このエントリーをはてなブックマークに追加


ID 65754
FullText URL
Author
Kimura, Shuhei Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University ORCID Kaken ID
Hosokawa, Mio Morizane Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Shiode, Yusuke Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID
Matoba, Ryo Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kanzaki, Yuki Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Goto, Yasuhito Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kanenaga, Keisuke Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Suzuki, Etsuji Department of Epidemiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons researchmap
Morizane, Yuki Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons
Abstract
Purpose To identify a method for accurately measuring preoperative axial length (AL) in cases of rhegmatogenous retinal detachment (RRD).
Study design Retrospective study.
Methods This retrospective study included 83 eyes of 83 patients who underwent vitrectomy for RRD and had both preoperative and postoperative data for AL. Preoperative AL measurements for the affected eye were obtained using ultrasound (aUS-AL) and compared with those for affected and fellow eyes measured using optical biometry (aOB-AL and fOB-AL, respectively). Absolute differences between preoperative aUS-AL, aOB-AL, or fOB-AL measurements and postoperative AL (aPost-AL) were examined.
Results In the 41 eyes without macular detachment, the absolute difference between aOB-AL and aPost-AL (0.06±0.07 mm) was significantly smaller than between aUS-AL and aPost-AL (0.21±0.18 mm) and that between fOB-AL and aPost-AL (0.29±0.35 mm) (P = 0.017 and P < 0.001, respectively). In the 42 eyes with macular detachment, the absolute difference between aOB-AL and aPost-AL (1.22±2.40 mm) was significantly larger than between aUS-AL and aPost-AL (0.24±0.24 mm) and between fOB-AL and aPost-AL (0.35±0.49 mm) (P = 0.006, P = 0.016, respectively).
Conclusion The current findings suggest that aOB-AL is more accurate than aUS-AL or fOB-AL in cases of RRD without macular detachment, while aUS-AL or fOB-AL is more accurate than aOB-AL in cases with macular detachment.
Keywords
Axial length
Rhegmatogenous retinal detachment
Macular detachment
Fourier-domain optic biometry
Ultrasound
Note
This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s10384-023-01018-2
This fulltext file will be available in Aug. 2024.
Published Date
2023-08-10
Publication Title
Japanese Journal of Ophthalmology
Volume
volume67
Issue
issue6
Publisher
Springer Science and Business Media LLC
Start Page
645
End Page
651
ISSN
0021-5155
NCID
AA00691177
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
Copyright Holders
© Japanese Ophthalmological Society 2023
File Version
author
PubMed ID
DOI
Web of Science KeyUT
Related Url
isVersionOf https://doi.org/10.1007/s10384-023-01018-2
Citation
Kimura, S., Hosokawa, M.M., Shiode, Y. et al. Accuracy of ultrasound vs. Fourier-domain optic biometry for measuring preoperative axial length in cases of rhegmatogenous retinal detachment. Jpn J Ophthalmol 67, 645–651 (2023). https://doi.org/10.1007/s10384-023-01018-2