JaLCDOI 10.18926/AMO/30731
FullText URL fulltext.pdf
Author Mukai, Takashi| Sato, Shuhei| Iguchi, Toshihiro| Mimura, Hidefumi| Yasui, Kotaro| Gobara, Hideo| Saika, Takashi| Nasu, Yasutomo| Kumon, Hiromi| Kanazawa, Susumu|
Abstract We quantitatively evaluated total and individual renal function by technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) renal scintigraphy before and after radiofrequency ablation (RFA) of renal tumors. Eleven patients who underwent Tc-99m MAG3 renal scintigraphy 1 week before and after RFA were evaluated (7 men and 4 women ; age range : 23-83 years ; mean age : 60.6 years). Five patients had solitary kidneys, and five had normally or minimally functioning contralateral kidneys. One patient had a renal cell carcinoma in the contralateral kidney. One patient with a solitary kidney underwent RFA a second time for a residual tumor. In patients with a solitary kidney, MAG3 clearance decreased after 5 of 6 RFAs, and in patients with a normally functioning contralateral kidney, MAG3 clearance decreased after 4 of 5 RFAs, but no significant differences were observed between before and after treatments. In addition to the total MAG3 clearance, the split MAG3 clearance was evaluated in patients with a normally functioning contralateral kidney. MAG3 clearance decreased in 4 of 5 treated kidneys, while it adversely increased in the contralateral kidneys after 4 of 5 RFAs. No significant differences, however, were observed between before and after treatments. The results of our study revealed no significant differences in sCr, BUN, CCr, or MAG3 clearance between pre- and post-RFA values. These results support data regarding the functional impact and safety of renal RFA in published reports. We evaluated total and individual renal function quantitatively using Tc-99m MAG3 renal scintigraphy before and after treatment. This scintigraphy was very useful in assessing the effects of RFA on renal function.
Keywords kidney renal tumor radiofrequency ablation Tc-99m MAG3 renal scintigraphy individual renal function
Amo Type Article
Publication Title Acta Medica Okayama
Published Date 2006-04
Volume volume60
Issue issue2
Publisher Okayama University Medical School
Start Page 85
End Page 91
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
File Version publisher
Refereed True
Web of Science KeyUT 000237001900003
JaLCDOI 10.18926/AMO/31981
FullText URL fulltext.pdf
Author Ohtsuki, Shinnichi| Baba, Kenji| Kataoka, Kohichi| Ohno, Naoki| Okamoto, Yoshio| Ishino, Kozo| Kawada, Masaaki| Sano, Shunji| Sato, Shuhei| Morishima, Tsuneo|
Abstract

We investigated the usefulness of helical computed tomography(CT)in the morphological diagnosis of pulmonary vein stenosis, particularly that in infants and small children. In total, 20 helical CT examinations were performed in 10 post-operative cases of Total Anomalous Pulmonary Venous Drainage(TAPVD), 3 cases of single right ventricle, and 1 case of single left ventricle. In all cases, distinct morphological imaging was possible. Pulmonary vein stenosis could be categorized into three types: (1)stenosis from the anastomosis of the common pulmonary vein (CPV)-the left atrium (LA) to the peripheral pulmonary vein; (2) stenosis only at the anastomosis of CPV-LA; and (3) stenosis due to compression by nearby organs. Coronal views by multiplanar reconstruction (MPR) provided morphological information along the up-down direction of the body axis. Morphological diagnosis of pulmonary vein stenosis is important in deciding prognosis and therapeutic regimens, and helical CT was considered useful for such diagnosis in our 14 young patients.

Keywords pulmonary vein stenosis helical CT
Amo Type Article
Publication Title Acta Medica Okayama
Published Date 2005-06
Volume volume59
Issue issue3
Publisher Okayama University Medical School
Start Page 93
End Page 98
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
File Version publisher
Refereed True
PubMed ID 16049562
Web of Science KeyUT 000230039100004
JaLCDOI 10.18926/AMO/31983
FullText URL fulltext.pdf
Author Fujie, Shunji| Okumura, Yoshihiro| Sato, Shuhei| Akaki, Shiro| Katsui, Kuniaki| Himei, Kengo| Takemoto, Mitsuhiro| Kanazawa, Susumu|
Abstract

We investigated the diagnostic capabilities of I-131, Tl-201, and Tc-99m-MIBI (hexakis-2-methoxyisobutyl- isonitrile) scintigraphy for thyroid cancer metastases after total thyroidectomy over the entire body and for every locus before and after thyroid bed ablation. After total thyroidectomy of thyroid cancer, 36 cases were subjected to I-131 treatment 64 times. They consisted of 17 men and 19 women with 31 papillary carcinomas and 5 follicular carcinomas. Their ages were 22--75(an average of 60.5+/-12.3) years. I-131 scintigraphy(I-131), Tl-201 scintigraphy(Tl-201), and Tc-99m- MIBI scintigraphy (Tc-99m-MIBI) were performed. We defined the metastases as those cases in which serum thyroglobulin (Tg)increased significantly or in which we were able to prove the lesions on CT (computed tomography), MRI (magnetic resonance imaging) or bone scintigram. Three radiology medical specialists visually evaluated each scintigram and calculated the sensitivity, specificity, and likelihood ratio. For whole-body sensitivity, both Tl-201 and Tc-99m-MIBI were high before ablation and I-131 was high after ablation. Before ablation, the negative likelihood ratio was less than 0.1 for Tl-201 and Tc-99m-MIBI, while the positive likelihood ratio was more than 10 for Tl-201. After ablation, the positive likelihood ratio for I-131, Tl-201, and Tc-99m-MIBI was more than 10. The sensitivity of the mediastinum was appropriate, except for I-131 before ablation, and the sensitivity of the lung before and after ablation was inferior for either tracer. The specificity of the cervix for I-131 before ablation was markedly deteriorated, but it increased after ablation.

Keywords I-131scintigraphy Tl-201 scintigraphy Tc-99m-MIBI scintigraphy thyroid cancer metastases
Amo Type Article
Publication Title Acta Medica Okayama
Published Date 2005-06
Volume volume59
Issue issue3
Publisher Okayama University Medical School
Start Page 99
End Page 107
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
File Version publisher
Refereed True
PubMed ID 16049563
Web of Science KeyUT 000230039100005
JaLCDOI 10.18926/AMO/32098
FullText URL fulltext.pdf
Author Yamamoto, Yasuhiro| Okumura, Yoshihiro| Sato, Shuhei| Maki, Kumi| Mukai, Takashi| Mifune, Hirofumi| Akaki, Shiro| Takeda, Yoshihiro| Kanazawa, Susumu| Hiraki, Yoshio|
Abstract

We studied the differentiation of thyroid nodules using fine-needle aspiration biopsy (FNA) and Tl-201 scintigraphy quantitative analysis. One-hundred and thirty-one thyroid nodules were examined: 83 follicular lesions (58 benign and 25 malignant lesions) and 48 non-follicular lesions (8 benign and 40 malignant lesions). During Tl-201 scintigraphy examinations, an early and a delayed image were acquired 10 and 120 min after an intravenous injection, respectively. The T/N ratio (counts of nodular lesion/counts of contralateral normal thyroid tissue) of each image was calculated quantitatively. We assessed the ability of the Tl-201 scintigraphy and of the FNA analysis to differentiate benign and malignant lesions and determined the cut-off levels for the assays. For the follicular lesions, the area under the ROC (Receiver Operating Characteristic) curve (Az) for the Tl-201 scintigraphy data was greater than that for the FNA data. For the non-follicular lesions, the Az for the FNA data was greater than that for the Tl-201 scintigraphy data. We set cut-off levels at 1.370 for follicular lesions, and 1.070 for non-follicular lesions. The sensitivity and specificity were 76% and 82.7% for follicular lesions, and 90% and 87.5% for non-follicular lesions, respectively. The overall accuracy of the analysis was 84.0%.

Keywords ?thyroid nodules fine-needle aspiration biopsy(FNA) Tl-201scintigraphy
Amo Type Article
Publication Title Acta Medica Okayama
Published Date 2004-04
Volume volume58
Issue issue2
Publisher Okayama University Medical School
Start Page 75
End Page 83
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
File Version publisher
Refereed True
PubMed ID 15255508
Web of Science KeyUT 000221043700003
JaLCDOI 10.18926/AMO/32116
FullText URL fulltext.pdf
Author Kurose, Taichi| Okumura, Yoshihiro| Sato, Shuhei| Yamamoto, Yasuhiro| Akaki, Shiro| Takeda, Yoshihiro| Kanazawa, Susumu| Ando, Akio| Date, Hiroshi| Shimizu, Nobuyoshi| Hiraki, Yoshio|
Abstract

We evaluated the respiratory functions of patients with pulmonary emphysema who underwent lung volume reduction surgery (LVRS) by the mean transit time (MTT) with Xe-133 lung ventilation scintigraphy, forced expiration volume in 1 sec (FEV1.0), residual volume (RV), distance walked in 6 min (6-min walk), and the Hugh-Jones classification (H-J classification) before and after LVRS. In 69 patients with pulmonary emphysema (62 men, 7 women; age range, 47-75 years; mean age, 65.4 years +/- 6.1, preoperative H-J classification, III (two were II)-V) who underwent LVRS, all preoperative and postoperative parameters (MTT 3 weeks after LVRS and the others 3 months after LVRS) were judged statistically by the Wilcoxon signed-ranks test and Odds ratio. Every postoperative parameter was improved with a significant difference (P < 0.05) compared to preoperative parameters. MTT at 3 weeks after LVRS was not associated with %FEV1.0 and the H-J classification at 3 months after LVRS, but was associated with RV and a 6-min walk at 3 months after LVRS. MTT was useful for the clinical evalution of aerobic capability after LVRS.

Keywords lung volume reduction surgery (LVRS) respiratory functions Xe-133 lung ventilation scintigraphy pulmonary emphysema
Amo Type Article
Publication Title Acta Medica Okayama
Published Date 2004-02
Volume volume58
Issue issue1
Publisher Okayama University Medical School
Start Page 7
End Page 15
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
File Version publisher
Refereed True
PubMed ID 15157006
Web of Science KeyUT 000189271100002
JaLCDOI 10.18926/AMO/46852
FullText URL 65_4_265.pdf
Author Kojima, Katsuhide| Kato, Katsuya| Oto, Takahiro| Mitsuhashi, Toshiharu| Shinya, Takayoshi| Sei, Tetsuro| Okumura, Yoshihiro| Sato, Shuhei| Miyoshi, Shinichiro| Kanazawa, Susumu|
Abstract To determine the effectiveness of living-donor lobar lung transplantation (LDLLT), it is necessary to predict the recipient's postoperative lung function. Traditionally, Date's formula, also called the segmental ratio, has used the number of lung segments to estimate the forced vital capacity (FVC) of grafts in LDLLT. To provide a more precise estimate of graft FVC, we calculated the volumes of the lower lobe and total lung using three-dimensional computed tomography (3D-CT) and the volume ratio between them. We calculated the volume ratio in 52 donors and tested the difference between the segmental volume ratios with a one-tailed t-test. We also calculated the predicted graft FVC in 21 LDLLTs using the segmental ratio pFVC(c) and the volume ratio pFVC(v), and then found the Pearson's correlation coefficients for both pFVC(c) and pFVC(v) with the recipients' actual FVC (rFVC) measured spirometrically 6 months after surgery. Significant differences were found between the segmental ratio and the average volume ratio for both sides (right, p=0.03;left, p=0.0003). Both pFVC(c) and pFVC(v) correlated significantly with rFVC at 6 months after surgery (p=0.007 and 0.006). Both the conventional and the volumetric methods provided FVC predictions that correlated significantly with measured postoperative FVC.
Keywords living-donor lobar lung transplantation 3D-CT volumetry
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2011-08
Volume volume65
Issue issue4
Publisher Okayama University Medical School
Start Page 265
End Page 268
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2011 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 21860533
Web of Science KeyUT 000294236700007
JaLCDOI 10.18926/AMO/47265
FullText URL 65_6_395.pdf
Author Harada, Sosuke| Sato, Shuhei| Suzuki, Etsuji| Okumura, Yoshihiro| Hiraki, Takao| Gobara, Hideo| Mimura, Hidefumi| Kanazawa, Susumu| Kaji, Mitsumasa| Fujiwara, Toshiyoshi|
Abstract The aim of the present study was to assess the diagnostic usefulness of Fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the prediction of local recurrence of malignant lung tumors by analyzing the pre-radiofrequency ablation (RFA) maximal standardized uptake value (SUVmax). We performed a historical cohort study of consecutive malignant lung tumors treated by RFA from January 2007 to May 2008 at Okayama University Hospital. We selected only lung tumors examined by PET/CT within 90 days before RFA and divided them (10 primary and 29 metastatic) into 3 groups according to their tertiles of SUVmax. We calculated recurrence odds ratios in the medium group and the high group compared to the low group using multivariate logistic analysis. After we examined the relationship between SUVmax and recurrence in a crude model, we adjusted for some factors. Tumors with higher SUVmax showed higher recurrence odds ratios (medium group;1.84, high group;4.14, respectively). The tumor size also increased the recurrence odds ratio (2.67);we thought this was mainly due to selection bias because we excluded tumors less than 10mm in diameter. This study demonstrated the pre-RFA SUVmax in PET/CT may be a prognostic factor for local recurrence of malignant lung tumors.
Keywords fluorodeoxyglucose (FDG) positron emission tomography (PET) standardized uptake value (SUV) radiofrequency ablation (RFA) lung
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2011-12
Volume volume65
Issue issue6
Publisher Okayama University Medical School
Start Page 395
End Page 402
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2011 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 22189480
Web of Science KeyUT 000298516900006
JaLCDOI 10.18926/AMO/49044
FullText URL 66_6_475.pdf
Author Hase, Soichiro| Mitsumori, Akihito| Inai, Ryota| Takemoto, Mitsuhiro| Matsubara, Shinichiro| Akamatsu, Nobuo| Fujisawa, Masayoshi| Joja, Ikuo| Sato, Shuhei| Kanazawa, Susumu|
Abstract The purpose of this study is to evaluate the diagnostic usefulness of magnetic resonance imaging (MRI) characteristics of endometrial polyps in order to differentiate them from other endometrial lesions. MRI was retrospectively reviewed in 40 patients with pathologically proven endometrial polyps. Special attention was paid to the sizes, shapes, margins, internal structures, signal intensities, and post-contrast enhancement patterns. A central fibrous core, intratumoral cysts, and hemorrhage were seen in 30 (75%), 22 (55%), and 14 (35%) patients, respectively. The predominant signal intensity of the lesions showed iso-to slightly low signal intensity relative to the endometrium on T2-weighted images in 36 (90%), low signal intensity on diffusion-weighted images in 32 (80%), and strong or moderate enhancement on enhanced T1-weighted images in 28 patients (70%), respectively. In 32 (80%) patients, the endometrial polyps showed global or partial early enhancement. On dynamic study, rapid enhancement with a persistent strong enhancement pattern was seen in 17 (42.5%) and a gradually increasing enhancement pattern was seen in 17 patients (42.5%). These MRI features can be helpful to distinguish the endometrial polyps from various other endometrial lesions.
Keywords endometrial polyp central fibrous core intratumoral cyst magnetic resonance imaging (MRI) uterus
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2012-12
Volume volume66
Issue issue6
Publisher Okayama University Medical School
Start Page 475
End Page 485
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2012 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 23254582
Web of Science KeyUT 000312966100007
Related Url http://ousar.lib.okayama-u.ac.jp/metadata/49723
JaLCDOI 10.18926/AMO/49669
FullText URL 67_2_105.pdf
Author Alafate, Aierken| Shinya, Takayoshi| Okumura, Yoshihiro| Sato, Shuhei| Hiraki, Takao| Ishii, Hiroaki| Gobara, Hideo| Kato, Katsuya| Fujiwara, Toshiyoshi| Miyoshi, Shinichiro| Kaji, Mitsumasa| Kanazawa, Susumu|
Abstract We retrospectively evaluated the accumulation of fluorodeoxy glucose (FDG) in pulmonary malignancies without local recurrence during 2-year follow-up on positron emission tomography (PET)/computed tomography (CT) after radiofrequency ablation (RFA). Thirty tumors in 25 patients were studied (10 non-small cell lung cancers;20 pulmonary metastatic tumors). PET/CT was performed before RFA, 3 months after RFA, and 6 months after RFA. We assessed the FDG accumulation with the maximum standardized uptake value (SUVmax) compared with the diameters of the lesions. The SUVmax had a decreasing tendency in the first 6 months and, at 6 months post-ablation, FDG accumulation was less affected by inflammatory changes than at 3 months post-RFA. The diameter of the ablated lesion exceeded that of the initial tumor at 3 months post-RFA and shrank to pre-ablation dimensions by 6 months post-RFA. SUVmax was more reliable than the size measurements by CT in the first 6 months after RFA, and PET/CT at 6 months post-RFA may be more appropriate for the assessment of FDG accumulation than that at 3 months post-RFA.
Keywords fluorodeoxy glucose (FDG) positron emission tomography (PET) standardized uptake value (SUV) radiofrequency ablation (RFA) non-small cell lung cancer (NSCLC)
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2013-04
Volume volume67
Issue issue2
Publisher Okayama University Medical School
Start Page 105
End Page 112
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2013 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 23603927
Web of Science KeyUT 000317801700005
Related Url http://ousar.lib.okayama-u.ac.jp/metadata/50688
JaLCDOI 10.18926/AMO/50407
FullText URL 67_3_145.pdf
Author Ishihara, Setsuko| Taira, Naruto| Kawasaki, Kensuke| Ishibe, Youichi| Mizoo, Taeko| Nishiyama, Keiko| Iwamoto, Takayuki| Nogami, Tomohiro| Motoki, Takayuki| Shien, Tadahiko| Matsuoka, Junji| Doihara, Hiroyoshi| Komoike, Yoshifumi| Sato, Shuhei| Kanazawa, Susumu|
Abstract A high mammographic breast density is considered to be a risk factor for breast cancer. However, only a small number of studies on the association between breast density and lifestyle have been performed. A cross-sectional study was performed using a survey with 29 questions on life history and lifestyle. The breast density on mammography was classified into 4 categories following the BI-RADS criteria. The subjects were 522 women with no medical history of breast cancer. The mean age was 53.3 years old. On multivariate analysis, only BMI was a significant factor determining breast density in premenopausal women (parameter estimate, -0.403;p value, 0.0005), and the density decreased as BMI rose. In postmenopausal women, BMI (parameter estimate, -0.196;p value, 0.0143) and number of deliveries (parameter estimate, -0.388;p value, 0.0186) were significant factors determining breast density;breast density decreased as BMI and number of deliveries increased. Only BMI and number of deliveries were identified as factors significantly influencing breast density. BMI was inversely correlated with breast density before and after menopause, whereas the influence of number of deliveries on breast density was significant only in postmenopausal women in their 50 and 60s.
Keywords breast cancer mammographic breast density life style body mass index
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2013-06
Volume volume67
Issue issue3
Publisher Okayama University Medical School
Start Page 145
End Page 151
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2013 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 23804137
Web of Science KeyUT 000320747900003
Related Url http://ousar.lib.okayama-u.ac.jp/metadata/50646
JaLCDOI 10.18926/AMO/54505
FullText URL 70_4_285.pdf
Author Tanaka, Takashi| Gobara, Hideo| Inai, Ryota| Iguchi, Toshihiro| Tada, Akihiro| Sato, Shuhei| Yanai, Hiroyuki| Kanazawa, Susumu|
Abstract We present a case of a 66-year-old man with esophageal carcinoma. 18Fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for evaluating distant metastasis and staging revealed 18F-FDG uptake in the third lumbar vertebra and other vertebrae. Magnetic resonance imaging could not differentiate bone metastases from benign bone lesions. We considered the possibility of bone marrow reconversion. 111Indium chloride (111In-Cl3) scintigraphy with single-photon emission computed tomography/computed tomography (SPECT/CT) revealed erythroid bone marrow components in the bone lesions. The diagnosis of bone marrow reconversion was pathologically confirmed by a bone biopsy of the third lumbar vertebra. The patient underwent esophagectomy and has remained disease-free in the 2 years since. To the best of our knowledge, this is the first report to describe the usefulness of 111In-Cl3 with SPECT/CT for the diagnosis of bone marrow reconversion.
Keywords 111Indium chloride scintigraphy SPECT/CT bone marrow reconversion 18F-FDG PET/CT bone metastasis
Amo Type Case Report
Publication Title Acta Medica Okayama
Published Date 2016-08
Volume volume70
Issue issue4
Publisher Okayama University Medical School
Start Page 285
End Page 289
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2016 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 27549674
Web of Science KeyUT 000384748600009
JaLCDOI 10.18926/AMO/54976
FullText URL 71_2_91.pdf
Author Ogawa, Nanako| Sato, Shuhei| Ida, Kentaro| Kato, Katsuya| Ariyoshi, Yuichi| Wada, Koichiro| Nasu, Yasutomo| Kanazawa, Susumu|
Abstract The aim of this study was to investigate the utility of single-source dual-energy computed tomography (SS-DECT) composition analysis in characterizing different types of urinary stones and differentiating them from phleboliths. This study included 29 patients with urinary stones who were scheduled for surgery. All patients were scanned, first using single-energy computed tomography acquisition and then DECT acquisition on SS-DECT. Dual-energy data were archived to a Gemstone spectral imaging (GSI) viewer (GE Healthcare, Milwaukee, WI, USA). Hounsfield units (HU) and effective atomic numbers (Zeff) were estimated using the GSI viewer. The results of dual-energy analysis were compared with the biochemical constitution of the stones. The chemical analysis determined that the stones included 32 calcium-based, 6 cystine and 1 struvite stone. Both HU and Zeff values were helpful in differentiating calcium-based stones from cystine and struvite stones and phleboliths. The Zeff values of phleboliths were significantly higher than those for struvite and cystine stones, whereas it was difficult to distinguish phleboliths from struvite and cystine stones using the HU values. Composition analysis using SS-DECT is helpful for distinguishing urinary stone types and discriminating phleboliths from urinary stones. Zeff values may be more useful than HU values for differentiating urinary stones from phleboliths.
Keywords single-source dual-energy computed tomography effective atomic number urinary stone phlebolith
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2017-04
Volume volume71
Issue issue2
Publisher Okayama University Medical School
Start Page 91
End Page 96
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2017 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 28420889
JaLCDOI 10.18926/AMO/54978
FullText URL 71_2_105.pdf
Author Shinya, Takayoshi| Tanaka, Takashi| Soh, Junichi| Matsushita, Toshi| Sato, Shuhei| Toyooka, Shinichi| Yoshino, Tadashi| Miyoshi, Shinichiro| Kanazawa, Susumu|
Abstract We retrospectively assessed the dual-time-point (DTP) F-18 FDG PET/CT findings of thymic epithelial neoplasms (TENs) and investigated the diagnostic capacity of PET/CT compared to that of CT for predicting carcinoma. We calculated the ratio of the standardized uptake value of the tumor and that of the aortic arch (T/M ratio) for both the 90-min early scan and the 2-h delayed scan in 56 TEN patients. We used a multivariate logistic regression (MLR) analysis to estimate the CT features of carcinoma. We compared the diagnostic capacities of PET/CT and chest CT using receiver operating characteristic (ROC) analyses. The ROC curve revealed that the appropriate cut-off T/M ratio value for the highest accuracy was 2.39 with 75.0% accuracy. The area under the curve (AUC) was 0.855. The statistical analyses for DTP scans of 35 TEN patients demonstrated 74.3% accuracy and 0.838 AUC for the early scan versus 82.9% and 0.825 for the delayed scan. The MLR analysis indicated that mediastinal fat infiltration was a predictor of carcinoma. The ROC curve obtained for the model yielded an AUC of 0.853. Delayed scanning could improve the diagnostic capacity for carcinoma. The T/M ratio and mediastinal fat infiltration are predictive of carcinoma with moderate diagnostic accuracy.
Keywords thymic epithelial neoplasm thymic carcinoma thymoma dual-time-point PET/CT chest CT
Amo Type Original Article
Publication Title Acta Medica Okayama
Published Date 2017-04
Volume volume71
Issue issue2
Publisher Okayama University Medical School
Start Page 105
End Page 112
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language English
Copyright Holders CopyrightⒸ 2017 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 28420891
Author 佐藤 修平|
Published Date 2000-03-25
Publication Title
Content Type Thesis or Dissertation
Author Satoh, Shuhei| Kitagawa, Takahiro| Satoh, Nobuo| Togami, Izumi| Kimoto, Shin| Hiraki, Yoshio| Uno, Satoru| Kumon, Hiromi| Ohmori, Hiroyuki|
Published Date 1991
Publication Title 岡山医学会雑誌
Volume volume103
Issue issue11-12
Content Type Journal Article
Author 佐藤 修平|
Published Date 1999-07-25
Publication Title 日本醫學放射線學會雜誌
Volume volume59
Issue issue8
Content Type Journal Article