このエントリーをはてなブックマークに追加
ID 59951
JaLCDOI
FullText URL
74_3_209.pdf 2.71 MB
Author
Matsui, Yusuke Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Hiraki, Takao Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
Iguchi, Toshihiro Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Sakurai, Jun Center for Innovative Clinical Medicine
Uka, Mayu Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Masaoka, Yoshihisa Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Gobara, Hideo Division of Medical Informatics, Okayama University Hospital
Kanazawa, Susumu Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons
Abstract
An aspiration-type semi-automatic cutting biopsy needle enables tissue cutting during application of negative pressure, which is expected to contribute to a larger amount of specimen. The aim of the present study was to evaluate this novel needle in a clinical setting. Patients who underwent image-guided percutaneous biopsy for lung or renal masses were enrolled. Cutting biopsy was performed with and without aspiration during each procedure. The specimens were weighed using an electronic scale. The weights were compared between specimens obtained with and without aspiration using a paired t-test. The data from 45 lung and 30 renal biopsy procedures were analyzed. In lung biopsy, the mean±standard deviation weights of specimens obtained with and without aspiration were 2.20±1.05 mg and 2.24±1.08 mg, respectively. In renal biopsy, the mean weights were 6.52±2.18 mg and 6.42±1.62 mg, respectively. The weights were not significantly different between specimens obtained with and without aspiration either in lung (p=0.799) or renal (p=0.789) biopsies. The application of negative pressure with the aspiration-type semi-automatic cutting biopsy needle did not contribute to an increase in the amount of the specimen obtained in lung and renal biopsies.
Keywords
biopsy
cutting needle
aspiration
clinical study
Amo Type
Original Article
Publication Title
Acta Medica Okayama
Published Date
2020-06
Volume
volume74
Issue
issue3
Publisher
Okayama University Medical School
Start Page
209
End Page
214
ISSN
0386-300X
NCID
AA00508441
Content Type
Journal Article
language
English
Copyright Holders
CopyrightⒸ 2020 by Okayama University Medical School
File Version
publisher
Refereed
True
PubMed ID
Web of Science KeyUT
NAID