このエントリーをはてなブックマークに追加
ID 57464
FullText URL
Author
Masuda, T. Research Institute for Interdisciplinary Science, Okayama University ORCID Kaken ID publons researchmap
Hiraki, T. Research Institute for Interdisciplinary Science, Okayama University
Kaino, H. Research Institute for Interdisciplinary Science, Okayama University
Kishimoto, S. High Energy Accelerator Research Organization
Miyamoto, Y. Research Institute for Interdisciplinary Science, Okayama University
Okai, K. Research Institute for Interdisciplinary Science, Okayama University
Okubo, S. Research Institute for Interdisciplinary Science, Okayama University
Ozaki, R. Research Institute for Interdisciplinary Science, Okayama University
Sasao, N. Research Institute for Interdisciplinary Science, Okayama University
Suzuki, K. Research Institute for Interdisciplinary Science, Okayama University
Uetake, S. Research Institute for Interdisciplinary Science, Okayama University
Yoshimi, A. Research Institute for Interdisciplinary Science, Okayama University
Yoshimura, K. Research Institute for Interdisciplinary Science, Okayama University
Abstract
This paper reports on the demonstration of a high-rate energy measurement technique using a thin depletion layer silicon avalanche photodiode (Si-APD). A dedicated amplitude-to-time converter is developed to realize simultaneous energy and timing measurement in a high rate condition. The energy response of the system is systematically studied by using monochromatic X-ray beam with an incident energy ranging from 6 to 33 keV. The obtained energy spectra contain clear peaks and tail distributions. The peak fraction monotonously decreases as the incident photon energy increases. This phenomenon can be explained by considering the distribution of the energy deposit in silicon, which is investigated by using a Monte Carlo simulation.
Keywords
Avalanche photodiode
X-ray
Published Date
2019-01-01
Publication Title
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume
volume913
Publisher
Elsevier Science
Start Page
72
End Page
77
ISSN
01689002
NCID
AA10529991
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
File Version
author
DOI
Web of Science KeyUT
Related Url
isVersionOf https://doi.org/10.1016/j.nima.2018.10.029
Citation
T. Masuda, T. Hiraki, H. Kaino, S. Kishimoto, Y. Miyamoto, K. Okai, S. Okubo, R. Ozaki, N. Sasao, K. Suzuki, S. Uetake, A. Yoshimi, K. Yoshimura, Energy response of X-rays under high flux conditions using a thin APD for the energy range of 6–33 keV, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 913, 2019, Pages 72-77, ISSN 0168-9002, https://doi.org/10.1016/j.nima.2018.10.029.
Funder Name
Japan Society for the Promotion of Science
助成番号
15H03661 : Study on Thorium-229 low-lying isomeric state
17K14291 : トリウム229極低励起エネルギー準位観測のための高時間分解能X線検出器の開発
18H01230 : Study on thorium-229 Low-lying Isomer state and its application for fundamental physics Research Project
18H04353 : 物理定数恒常性測定の飛躍的精度向上に向けた、原子核のレーザー励起の実現 Publicly