ID | 20337 |
Eprint ID | 20337
|
FullText URL | |
Title Alternative | The basic study on measuring method of contamination of the ground and the effective porosity by using dielectric constant measuring system
|
Author |
Kim, Man-il
|
Abstract | For evaluating subsurface contamination, sampling method (boring) is commonly used, but this method cannot monitor the change of in-situ contamination and concentration with respect to time. The purpose of this study is to develop a measuring system for subsurface contamination in which a so-called FDR (Frequency Domain Refiectometry) and FDR-V (with Vector network analyzer) system was employed to measure the salinity and oil contaminant. This FDR and FDR-V method is a coaxial probe method, which allows the measurement of the dielectric. The experimental study indicates the possibility in measuring both the contaminant concentration and volumetric moisture content. In addition, the method for obtaining the effective porosity using this equipment was shown. Concretely, the sensor was inserted in the ground, and the liquid in which the dielectric constant differed on the water in the circumference was injected, and the method for obtaining the effective porosity from the change of the dielectric constant was proposed.
|
Keywords | Dielectric constant
Contamination
Frequency Domain Refiectometry
In-situ
Effective porosity
|
Note | 論文
|
Published Date | 2003-08
|
Publication Title |
環境制御
|
Publication Title Alternative | Environmental Research and Control
|
Volume | volume25
|
Publisher | 岡山大学環境管理センター
|
Publisher Alternative | Okayama University Administration Center for Environmental Science and Technology
|
Start Page | 19
|
End Page | 24
|
ISSN | 0917-1533
|
NCID | AN1024789X
|
Content Type |
Departmental Bulletin Paper
|
language |
Japanese
|
File Version | publisher
|
Refereed |
True
|
Eprints Journal Name | erc
|