このエントリーをはてなブックマークに追加
ID 63864
FullText URL
Author
Ahmed, Feroz Graduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University
Shimizu, Masashi Graduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University
Wang, Jin Graduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University
Sakai, Kenji Graduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University ORCID Kaken ID publons researchmap
Kiwa, Toshihiko Graduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University ORCID Kaken ID publons researchmap
Abstract
The fabrication of microflow channels with high accuracy in terms of the optimization of the proposed designs, minimization of surface roughness, and flow control of microfluidic parameters is challenging when evaluating the performance of microfluidic systems. The use of conventional input devices, such as peristaltic pumps and digital pressure pumps, to evaluate the flow control of such parameters cannot confirm a wide range of data analysis with higher accuracy because of their operational drawbacks. In this study, we optimized the circular and rectangular-shaped microflow channels of a 100 mu m microfluidic chip using a three-dimensional simulation tool, and analyzed concentration profiles of different regions of the microflow channels. Then, we applied a deep learning (DL) algorithm for the dense layers of the rectified linear unit (ReLU), Leaky ReLU, and Swish activation functions to train and test 1600 experimental and interpolation of data samples which obtained from the microfluidic chip. Moreover, using the same DL algorithm, we configured three models for each of these three functions by changing the internal middle layers of these models. As a result, we obtained a total of 9 average accuracy values of ReLU, Leaky ReLU, and Swish functions for a defined threshold value of 6 x 10(-5) using the trial-and-error method. We applied single-to-five-fold cross-validation technique of deep neural network to avoid overfitting and reduce noises from data-set to evaluate better average accuracy of data of microfluidic parameters.
Keywords
microfluidics
fluid dynamics
3D simulation
ReLU dense layers
Leaky ReLU
swish activation functions
deep learning model
Published Date
2022-08-20
Publication Title
Micromachines
Volume
volume13
Issue
issue8
Publisher
MDPI
Start Page
1352
ISSN
2072-666X
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
Copyright Holders
© 2022 by the authors.
File Version
publisher
PubMed ID
DOI
Web of Science KeyUT
Related Url
isVersionOf https://doi.org/10.3390/mi13081352
License
https://creativecommons.org/licenses/by/4.0/