このエントリーをはてなブックマークに追加
ID 61720
FullText URL
Author
Furumatsu, Takayuki Department of Orthopaedic Surgery, Okayama University Hospital Kaken ID publons
Hiranaka, Takaaki Department of Orthopaedic Surgery, Okayama University Hospital
Kodama, Yuya Department of Orthopaedic Surgery, Okayama University Hospital
Kamatsuki, Yusuke Department of Orthopaedic Surgery, Okayama University Hospital
Okazaki, Yuki Department of Orthopaedic Surgery, Okayama University Hospital
Yamawaki, Tadashi Department of Orthopaedic Surgery, Okayama University Hospital
Endo, Hirosuke Department of Orthopaedic Surgery, Okayama University Hospital Kaken ID publons
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Hospital
Abstract
Background
The lengths of the anteromedial bundle (AMB) and posterolateral bundle (PLB) change during knee motion during double-bundle anterior cruciate ligament (ACL) reconstruction. However, the actual intra-articular graft length would be affected by the bone tunnel position and tunnel creation angle during ACL reconstruction. The aim of this study was to investigate the intra-articular length change of the AMB and PLB in patients who underwent anatomic double-bundle ACL reconstruction.
Hypothesis
We hypothesized that the PLB would show a more dynamic length change pattern than the AMB during knee flexion at ACL reconstruction.
Methods
Thirty-two patients (16 men and 16 women) who had isolated ACL injuries with intact menisci were investigated. Anatomic double-bundle ACL reconstructions were performed using semitendinosus tendon autografts at a mean age of 30.6 years. The graft and tunnel lengths were measured intraoperatively. Intra-articular graft lengths and length changes were calculated at 0° and 90° of knee flexion during ACL reconstruction. Intraoperative data were collected prospectively, and analyses were performed retrospectively.
Results
The intra-articular length of the AMB at 0° of knee flexion was 28.1±5.5mm. At 90° of knee flexion, the AMB intra-articular length decreased to 25.6±4.8mm. The intra-articular length of the PLB decreased to 17.7±4.6mm at 90° of knee flexion compared to 22.0±4.2mm at 0° of knee flexion. Changes in the intra-articular graft length during knee flexion were detected more in the PLB (4.1mm) than in the AMB (2.0mm, p=0.01).
Discussion
This study demonstrated that the intra-articular length change of the PLB during knee motion was larger than that of the AMB in anatomic double-bundle ACL reconstructions with semitendinosus tendon autografts and suspensory femoral fixation devices. Level of evidenceIV ; retrospective cohort study.
Note
© 2021 Elsevier Masson SAS. This manuscript version is made available under the CC-BY-NC-ND 4.0 License.http://creativecommons.org/licenses/by-nc-nd/4.0/.This is the accepted manuscript version. The formal published version is available at [https://doi.org/10.1016/j.rcot.2021.01.008] .
Published Date
2021-04-30
Publication Title
Revue de Chirurgie Orthopédique et Traumatologique
Volume
volume107
Issue
issue2
Publisher
Elsevier Masson SAS
Start Page
244
End Page
245
ISSN
18770517
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
Copyright Holders
© 2021 Elsevier Masson SAS. All rights reserved.
File Version
author
DOI
Related Url
isVersionOf https://doi.org/10.1016/j.rcot.2021.01.008
License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Citation
Takayuki Furumatsu, Takaaki Hiranaka, Yuya Kodama, Yusuke Kamatsuki, Yuki Okazaki, Tadashi Yamawaki, Hirosuke Endo, Toshifumi Ozaki, Les longueurs intra-articulaires des greffons à double faisceau peuvent changer pendant la flexion du genou : mesures peropératoires lors de reconstructions anatomiques du ligament croisé antérieur, Revue de Chirurgie Orthopédique et Traumatologique, Volume 107, Issue 2, 2021, Pages 244-245, ISSN 1877-0517, https://doi.org/10.1016/j.rcot.2021.01.008.
Open Access (Publisher)
non-OA
Open Archive (publisher)
Non-OpenArchive