Flow Injection Analysis for Hydrogen Peroxide in Environmental Waters
Author
Mukuno, Takashi
Akizawa, Hiromichi
Mifune, Masaki Kaken ID publons
Saito, Yutaka
Abstract
先に開発した過酸化水素のフローインジェクション分析法(FIA)のシステムや触媒カラムに詳細な検討を加え,ppbレベルの過酸化水素の定量法を開発した。また,本研究で得られたFIAを用いて,57~944ppbになるように過酸化水素を雨水に添加し,回収実験を行った。その結果,回収率と再現性とも良好で,化学発光法より優れていた。なお,FIAでの検出下限は,約10ppbであった。
Abstract Alternative
We tried to determine a low-level hydrogen peroxide by using a flow injection analysis (FIA) which was reported in our previous paper. For this purpose, the constituents of the system including the catalytic column were re-examined in detail. As the result, we developed a new system of the FIA which is available for the determination of ppb-order hydrogen peroxide. When hydrogen peroxide spiked in rain-waters(57-944ppb)was analyzed by the FIA, better recovery and reproducibility were attained compared to chemiluminescent analyses. The lower-limit of determination was 10 ppb hydrogen peroxide.
Note
論文
Published Date
1998-08
Publication Title
環境制御
Publication Title Alternative
Environmental Research and Control
Volume
volume20
Publisher
岡山大学環境管理センター
Publisher Alternative
Okayama University Administration Center for Environmental Science and Technology
Start Page
22
End Page
26
ISSN
0917-1533
NCID
AN1024789X
Content Type
Departmental Bulletin Paper
language
Japanese
File Version
publisher
Refereed
True
Eprints Journal Name
erc