このエントリーをはてなブックマークに追加
ID 11531
JaLCDOI
Sort Key
7
FullText URL
Author
Abstract
For evaluating subsurface contamination, sampling method (boring) is commonly used, but this method cannot monitor the change of in-situ contamination and concentration with respect to time. The purpose of this study is to develop a measuring system for subsurface contamination in which a so-called FDR-V system (Frequency Domain Reflectometry with Vector network analyzer) was employed to measure the salinity contaminant. This FDR-V method is a coaxial probe method,which allows the measurement of the complex dielectric constant from 1GHz to 18GHz. The experimental study indicates the possibility in measuring both the salinity concentration and volumetric moisture content.
Keywords
Dielectric constant
Subsurface
Salinity concentration
Volumetric moisture content
Publication Title
岡山大学環境理工学部研究報告
Published Date
2001-02-28
Volume
volume6
Issue
issue1
Publisher
岡山大学環境理工学部
Publisher Alternative
Faculty of Environmental Science and Technology, Okayama University
Start Page
47
End Page
52
ISSN
1341-9099
NCID
AN10529213
Content Type
Departmental Bulletin Paper
OAI-PMH Set
岡山大学
language
English
File Version
publisher
NAID
Eprints Journal Name
fest