このエントリーをはてなブックマークに追加
ID 30206
FullText URL
Author
Gotoh, Yuji
Abstract

The alternating magnetic flux leakage testing is used for the detection of cracks in a steel plate. A new technique of how to detect plural cracks, which are located at a very short distance from each other, using the parallel (x-) component of the leakage flux density is proposed. The behavior of leakage flux is examined using a three-dimensional edge-based hexahedral finite-element method. The effects of dimensions of search coils and cracks on the detection accuracy are illustrated.

Keywords
coils
crack detection
eddy current testing
finite element analysis
magnetic flux
magnetic leakage
Note
Digital Object Identifier: 10.1109/TMAG.2003.810219
Published with permission from the copyright holder. This is the institute's copy, as published in Magnetics, IEEE Transactions on, May 2003, Volume 39, Issue 3, Part 1, Pages 1527-1530.
Publisher URL:http://dx.doi.org/10.1109/TMAG.2003.810219
Copyright © 2003 IEEE. All rights reserved.
Published Date
2003-5
Publication Title
Magnetics
Volume
volume39
Issue
issue3
Start Page
1527
End Page
1530
Content Type
Journal Article
language
English
Refereed
True
DOI
Submission Path
electricity_and_magnetism/159