Evaluation of renal function by the ultrasonic Doppler technique
Author
Kitagawa, Takahiro
Satoh, Nobuo
Togami, Izumi
Kimoto, Shin
Hiraki, Yoshio
Uno, Satoru
Kumon, Hiromi Kaken ID publons
Ohmori, Hiroyuki
Abstract
To evaluate the clinical application of the ultrasonic Doppler technique, renal arterial blood flow was measured in 7 normal subjects and 3 patients with renal dysfunction. For the purpose of correction of blood flow measured by the Doppler technique, some basic studies were performed. The ratio of peak diastolic to peak systolic velocity (D/S ratio) correlated well with both the creatinine clearance and the CA ratio calculated from the results of Dynamic CT. There was no correlation between the corrected velocity of the arterial blood flow and the creatinine clearance. The D/S ratio obtained by the ultrasonic Doppler technique is thought to be a useful parameter in the evaluation of the renal function. However, the Dynamic CT is thought to be superior in objectiveness to the ultrasonic Doppler technique.
Keywords
超音波パルスドップラ法
D/S 比
DCT
CA ratio
Note
原著
Published Date
1991
Publication Title
岡山医学会雑誌
Publication Title Alternative
Journal of Okayama Medical Association
Volume
volume103
Issue
issue11-12
Publisher
岡山医学会
Publisher Alternative
Okayama Medical Association
Start Page
1177
End Page
1181
ISSN
0030-1558
NCID
AN00032489
Content Type
Journal Article
Official Url
https://www.jstage.jst.go.jp/article/joma1947/103/11-12/103_11-12_1177/_article/-char/ja/
Related Url
http://www.okayama-u.ac.jp/user/oma/
language
Japanese
Copyright Holders
岡山医学会
File Version
publisher
Refereed
True
Eprints Journal Name
joma