ID | 15723 |
JaLCDOI | |
Sort Key | 15
|
FullText URL | |
Author |
Sano, Hiroya
Koga, Ryuji
Tanada Yoshihiro
|
Abstract | The maximally attainable accuracy of an airpollution monitoring system is investigated. The system is composed of a tunable pulsed dye laser as the light source, photodiodes as the opto-electric converter and a low noise electronic signal processor specifically designed by the authors. The extreme value of the accuracy is given in terms of the standard deviation of the attenuation. The value is 3.4×10(-4)[Nep√(pulse number)] for an averaged value for multiple laser shots. Also the wavelength reproduceability of a dye laser was examined, which resulted in that a computer should take a part in the wavelength control in order that this method should be feasible.
|
Publication Title |
Memoirs of the School of Engineering, Okayama University
|
Published Date | 1979-03-05
|
Volume | volume13
|
Publisher | 岡山大学工学部
|
Publisher Alternative | School of Engineering, Okayama University
|
Start Page | 195
|
End Page | 207
|
ISSN | 0475-0071
|
NCID | AA00733903
|
Content Type |
Departmental Bulletin Paper
|
OAI-PMH Set |
岡山大学
|
language |
English
|
File Version | publisher
|
NAID | |
Eprints Journal Name | mfe
|