1 32
ID 15655
JaLCDOI
Sort Key
3
FullText URL
Author
Nakata Takayoshi
Ishihara Yoshiyuki
Nakano Masanori
Abstract
When the distorted flux is induced in a magnetic circuit, the minor loops arise sometimes inside the major hysteresis loop. The area, accordingly the hysteresis loss of the minor loop,is affected by its amplitude and position, by the maximum flux density, by the quality of material, etc.. In this paper, we describe the experimental studies of the factors on the minor loop hysteresis loss. A method of getting the displacement factor of a minor loop which is placed at arbitrary position and has any amplitude is developed from our experimental results. Using this method, the core losses caused by the distorted flux can be calcuLated within the error less than three percent, even if the amplitude of the minor loop becomes near to the amplitude of the major loop.
Publication Title
Memoirs of the School of Engineering, Okayama University
Published Date
1973-07-20
Volume
volume8
Issue
issue1
Publisher
岡山大学工学部
Publisher Alternative
School of Engineering, Okayama University
Start Page
1
End Page
14
ISSN
0475-0071
NCID
AA00733903
Content Type
Departmental Bulletin Paper
OAI-PMH Set
岡山大学
language
English
File Version
publisher
NAID
Eprints Journal Name
mfe