このエントリーをはてなブックマークに追加
ID 15846
Eprint ID
15846
FullText URL
100_31.pdf 1.73 MB
Title Alternative
Effects of pneumoperitoneum on the vectorcardiogram obtained with the Frank lead system
Author
Terasaka, Ritsuko
Yamanari, Hiroshi
Togawa, Junichiro
Ihara, Keiko
Kobiki, Naoki
Hagihara, Hidenori
Matsuno, Shigeru
Matsubara, Katashi
Yamada, Nobuyuki
Yoshida, Hidenori
Saito, Daiji
Haraoka, Shoichi
Tsuji, Takao
Abstract
Vectorcardiograms were recorded with the Frank lead system during laparoscopy. Pneumoperitoneum produced the following significant vectorcardiographic changes: (1) The maximum spatial QRS vector increased in magnitude and shifted horizontally and slightly anteriorly. (2) The L/W ratio of the frontal QRS loop decreased. (3) The scalar data of each X, Y, Z lead of the QRS loop increased. In particular, the increases in R of all three leads and in S of lead Z were significant. These results suggest that the changes in the cardiac anatomic position due to lift of the diaphragma and a decrease of left ventricular end-diastolic volume might produce these vectorcardiographic changes during laparoscopy.
Keywords
腹腔鏡検査
vectorcardiogram
pneumoperitoneum
Published Date
1988
Publication Title
岡山医学会雑誌
Publication Title Alternative
Journal of Okayama Medical Association
Volume
volume100
Issue
issue1-2
Publisher
岡山医学会
Publisher Alternative
Okayama Medical Association
Start Page
31
End Page
36
ISSN
0030-1558
NCID
AN00032489
Content Type
Journal Article
Official Url
https://www.jstage.jst.go.jp/article/joma1947/100/1-2/100_1-2_31/_article/-char/ja/
Related Url
http://www.okayama-u.ac.jp/user/oma/index.html
language
Japanese
Copyright Holders
岡山医学会
File Version
publisher
Refereed
True
Eprints Journal Name