JaLCDOI 10.18926/21178
タイトル(別表記) Determination of copper and zinc in synovial fluid by atomic absorption spectrophotometry
フルテキストURL pitsr_048_013_023.pdf
著者 古野 勝志|
抄録 Copper (Cu) and zinc (Zn) in synovial fluids of 52 patients with rheumatoid arthritis (RA) and of 53 patients with osteoarthritis (OA) were determined using a HITACHI MODEL 207 atomic absorption spectrophotometer. Standard solution of Cu and Zn were 50μg, 100μg, 200μg and 300μg per 100 ml 20 v/v % glycerine containing 0.01 N-HCl. To 0.5ml synovial fluid, 50 units of hyaluronidase was added and then the mixture were incubated for 20 minutes at 37℃. Synovial fluid treated with hyaluronidase and standard solution of Cu and Zn were diluted five fold with deionized distillation water, then aspirated directly into the burner. The relative absorbance was expressed as scale reading by a HITACHI MODEL QPD-54 recoder. The mean recovery rate of Cu and Zn in synovial fluids were 102.0% and 101.9%. By this method the concentrations of Cu and Zn in 52 RA (12 males, 40 females) were 97.6±29.0 (S.D.) μg/100 ml and 83.9±40.1 (S.D.) μg/100 ml ; 97.3±27.1 (S.D.)μg/100 ml, 78.7±29.9 (S.D.) μg /100 ml in 12males and 97.7±29.5 (S.D.) μg/100 ml, 85.5±42.6 (S.D.) μg /100 ml in 40 females respectively. The concentrations of Cu and Zn in 53 OA (14 males, 39 females) were 46.9±14.5 (S.D.) μg/100 ml and 40.8±14.3 (S.D.) μg/100 ml; 47.3±9.7 (S.D.) JLg/100 ml, 45.1±19.0 (S.D.) μg/ 100 ml in 14 males and 46.8±15.8 (S.D.) μg/100 ml, 39.3±11.8 (S.D.) μg/100 ml in 39 females respectively. No sex differences of Cu and Zn values were observed in both RA and OA. In patients with RA, concentrations of Cu and Zn in synovial fluids were signifcantly higher than in OA in both sexes. There were positive correlation between the concentrations of Cu and Zn in 105 patients (RA and OA, r=0.74, p<0.01) , in 52 RA (r=0.54, p<0.01), in 53 OA (r=0.81, p<0.01). In patients with RA, there were no correlation between stage and concentrations of Cu and Zn in synovial fluids.
出版物タイトル 岡山大学温泉研究所報告
発行日 1979-03-25
48巻
開始ページ 13
終了ページ 23
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
NAID 120002311026
JaLCDOI 10.18926/21160
タイトル(別表記) The determination of uric acid using modified Patel's method
フルテキストURL pitsr_050_025_031.pdf
著者 西村 佳子| 青木 宏子| 御舩 政明|
抄録 N 13-b method for determination of uric acid by AutoAnalyzer- I was proposed from Technicon Corporation, but the sensitivity of this method was insufficient. According to the modification by Patel, good sensitivity was obtained for determining of uric acid, but insufficient separation between peaks was accompanied. To get good separation, Patel's method was reexamined by the authors, and the results were as follows. Sufficient separation was obtained by modifing the flow diagram of Patel's method. The mean recovery rates of uric acid added to serum and urine were 103.6% and 102.5%, and coefficients of variation were 1.27% and 1.05% respectively. The correlation between this modified Patel's method and the U.A. test Wako method was recognized (serum : n=95, r=0.97, urine : n=35, r =0.99). According to our modified method, uric acid concentration in serum of 68 subjects, were 5.8±0.9mg/100ml in 29 males and 4.4±0.8mg/100ml in 39 females.
出版物タイトル 岡山大学温泉研究所報告
発行日 1980-03-25
50巻
開始ページ 25
終了ページ 31
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
NAID 120002310944
JaLCDOI 10.18926/21139
タイトル(別表記) Isotopic Analysis of Rb and Sr Using a Full Automatic Thermal Ionization Mass Spectrometer
フルテキストURL pitsr_052_051_070.pdf
著者 加々美 寛雄| 岡野 修| 須藤 宏| 本間 弘次|
抄録 Analytical method for strontium isotope ratios and rubidium and strontium concentrations has been established using a full automatic thermal ionization mass spectrometer. The machine is a modified model "MAT 260" of Varian MAT LTD. Each of simultaneously loaded thirteen samples is successively analysed full automatically following to a specific controling program which has been selected as being most suitable for each sample. However, the most characteristic feature of this machine compared to other types is computer controled peak jumping and peak centering before measurment of the signal of each peak. By this the accuracy of isotopic measurement has been surprisingly improved. Analytical procedures are described in detail which include decomposition of samples, separation of Rb and Sr, loading samples on filament and mass spectrometry. Accuracy and reproducibility of isotope analyses are excellent : 43 separate analyses of standard sample NBS 987 over one year gave a mean (87)Sr/(86)Sr ratio of 0.710238 (normalized to the (88)Sr/(86)Sr ratio of 8.375209) with a value of 20δ of 0.000008. The ratio obtained is slightly higher than the value of 0.71014 given by NBS, but it is almost identical to the mean of recently reported twenty analyses. Our determinations for Rb and Sr concentrations of standard samples are as follows : JG-1, Rb 184.4 ppm, Sr 185.5 ppm; JB-l, Rb 41.5Ppm, Sr 448.4 ppm , each of which is near the mean of reported values for corresponding element of the sample (ANDO et al., 1974). Concentrations of Rb and Sr in pure water and regents used in chemical treatement of samples were also measured; a possible error due to the contamination is negligible for most geochemical samples.
出版物タイトル 岡山大学温泉研究所報告
発行日 1982-03-25
52巻
開始ページ 51
終了ページ 70
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
NAID 120002310968
JaLCDOI 10.18926/21118
タイトル(別表記) 好塩基球からのヒスタミン遊離に関する研究. 1 自動分析装置による全血からのヒスタミン遊離の測定
フルテキストURL pitsr_053_023_028.pdf
著者 谷崎 勝朗| 駒越 春樹| 周藤 真康| 御般 政明| 森永 寛| 大谷 純| 貴谷 光| 合田 吉徳| 多田 慎也| 木村 郁郎|
抄録 Histamine released from whole blood was determined by an automated fiuorometric histamine analysis system. The increased release of histamine from basophils by anti-IgE was observed in ten healthy subjects and 12 extrinsic asthma patients, while the release in 11 intrinsic asthma patients was significantly less as compared to that in healthy and extrinsic asthma subjects. House dust extract caused a significant increase in the histamine release from basophils of the extrinsic asthma patients who are sensitive to house dust. It was concluded from this study that histamine released from basophils could be easily determined by an automated analysis system and that the method is useful for the diagnosis and study of allergy.
出版物タイトル 岡山大学温泉研究所報告
発行日 1983-03-25
53巻
開始ページ 23
終了ページ 28
ISSN 0369-7142
言語 英語
論文のバージョン publisher
NAID 120002310945
JaLCDOI 10.18926/21114
タイトル(別表記) Determination of ferritin in serum and in synovial fluids of patients with rheumatoid arthritis
フルテキストURL pitsr_053_001_008.pdf
著者 古野 勝志| 森永 寛| 入野 昭三|
抄録 Ferritin in sera and in synovial fluids were determined by method of immunoradiometric assay (IRMA) and of radioimmunoassay (RIA). These methods have been proved to be reproducible. The coefficient variation was 7.4 to 9.9% in IRMA and 5.6 to 8.0% in RIA. There were a good correlation between methods of IRMA and of RIA (r=0.989). The mean recovery rate of ferritin in serum was 101.2% in IRMA and 101.0% in RIA, respectively. The determination of serum ferritin revealed a 16% reduction in average after preservation at -20℃ during over 100 days. The levels of serum ferritin in healthy controls were 131.4±52.1 ng/ml in 34 males and 58.4±39.9 ng/ml in 38 females. The sex differences were statisticalIy significant (p<0.01). Ferritin levels were shown to be below 30 ng/ml (the state of iron deficiency) in 2 of 34 (5.9%) males and in 8 of 38 (21%) females of healthy controls. The levels of serum ferritin in patients with rheumatoid arthritis (RA) were 337.0±293.4ng/ml in 10 males and 181.4±329.9ng/ml in 25 females. The serum ferritin in RA was significantly higher than in healthy controls of both sexes. The levels of ferritin in synovial fluids of patients with 14 RA and with 12 osteoarthritis were 2894±3017 ng/ml and 1429±1005 ng/ml, and no differences were observed in both groups.
出版物タイトル 岡山大学温泉研究所報告
発行日 1983-03-25
53巻
開始ページ 1
終了ページ 8
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
NAID 120002311016
JaLCDOI 10.18926/21102
タイトル(別表記) Research for carbon dioxide bathing IV, Thermal effect of artificial CO(2)-bathing
フルテキストURL 054_001_012.pdf
著者 萬 秀憲| 久保 裕一郎| 江口 泰輝| 砂川 満| 河本 知二| 古元 嘉昭| 古元 順子|
抄録 1) 炭酸塩と,コ-ク酸からなる錠剤型の「炭酸ガス浴剤」の保温作用を健康な男子8名について,サ-モグラフィーを用いて測定した. 入浴10分後の比較で明らかに,炭酸ガス浴はよく温まった結果,表面温度が高くなっている. 2) 腰痛,四肢冷感,その他の患者24名での臨床評価の結果,患者の90%以上が手足が温まり,湯ざめしにくいことを認めた.また,患者の85%は痛みがやわらぐことを認めた. 3) 主婦664名を対象とした使用評価の結果,常時手足の冷感を訴える者の63.6%,身体の疲労感・だるさ56.5%に効果を認めていることがわかった. 4) 副作用は全く認められなかった.
出版物タイトル 岡山大学温泉研究所報告
発行日 1984-03-25
54巻
開始ページ 1
終了ページ 12
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
JaLCDOI 10.18926/21085
タイトル(別表記) Automatic measurement of oxygen isotope ratio of water samples
フルテキストURL pitsr_056_027_034.pdf
著者 千葉 仁| 酒井 均| 安武 正敏|
抄録 The automatic sample preparation system for oxygen isotope analysis of natural water samples was constructed. The system is essentially a modification of that originally designed by W. Dansgaard in the University of Copenhagen. Sixty water samples of 5 ml each are automatically equilibrated with CO(2) of 30 ml NTP each within 4.5 hours. The equilibrated CO(2) gases are successively measured for their oxygen isotopic ratios by an automatic mas-sspectrometer, VG903. The time required for the measurement of the 60 CO(2) samples is about 15 hours; thus approximately 20 hours are required to complete the isotopic measurements of 60 water samples. The accuracy of the oxygen isotopic analyses is about 0.1%. The result of oxygen isotopic analyses by the automatic preparation system agrees with that of the conventional method within about +0.1%. The results indicate that the automatic preparation system is applicable for the oxygen isotope analysis of natural water samples.
出版物タイトル 岡山大学温泉研究所報告
発行日 1985-03-30
56巻
開始ページ 27
終了ページ 34
ISSN 0369-7142
言語 日本語
論文のバージョン publisher
NAID 120002310952
著者 岡山大学環境管理センター|
発行日 1982-11-01
出版物タイトル 岡山大学環境管理センター報
4巻
資料タイプ その他
著者 石井 猛| 末田 孝博| 門田 太司|
発行日 1993-06
出版物タイトル 岡山実験動物研究会報
10巻
資料タイプ 学術雑誌論文
著者 城 義信| 加瀬野 悟| 高橋 照男| 篠田 純男|
発行日 1990
出版物タイトル 環境制御
12巻
資料タイプ 紀要論文
著者 中桐 義忠| 東 義晴| 渋谷 光一| 後藤 佐知子| 丸山 敏則| 杉田 勝彦| 園山 真世| 森岡 泰樹| 稲村 圭司| 田原 誠司| 宇野 弘文| 門久 繁文| 井上 龍也| 平木 祥夫|
発行日 1995-12-20
出版物タイトル 環境制御
17巻
資料タイプ 紀要論文
著者 中桐 義忠| 東 義晴| 丸山 敏則| 渋谷 光一| 後藤 佐知子| 杉田 勝彦| 森岡 泰樹| 門久 繁文| 井上 龍也| 平木 祥夫|
発行日 1998-08
出版物タイトル 環境制御
20巻
資料タイプ 紀要論文
著者 西垣 誠| 小松 満| 金 萬鎰|
発行日 2003-08
出版物タイトル 環境制御
25巻
資料タイプ 紀要論文
著者 浅田 伸彦| 山崎 重雄|
発行日 2000-09
出版物タイトル 岡山実験動物研究会報
17巻
資料タイプ 学術雑誌論文
タイトル(別表記) 音韻符号化効率及び作動記憶容量と読解力の関係 ―日本人高校生の場合―
フルテキストURL Journ_Sci_Sch_007_041_050.pdf
著者 宮迫 靖静| Takatsuka, Shigenobu|
抄録 This article investigated into differences between first- and third-year senior high school students concerning: (a) the efficiencies of phonological coding and working memory capacities; and (b) the relationships of these two variables with reading comprehension. Also explored was whether the relationships were reflected in word-retaining strategies of the first-year students in the reading span tests for measuring working melnory capacities. The findings were: (a) students may improve their working memory capacities but may not improve the efficiencies of phonological coding during the first two years of senior high school; (b) the efficiency of phonological coding contributes to reading cOlnprehension more greatly for first-year students, but working metllory capacity contributes to reading comprehension for third-year students; and (c) the word-retaining strategies of first-year students reflect the relationships between the two variables and reading comprehension. The reasons for these findings were discussed and pedagogical implications were shown.
キーワード phonological coding (音韻符号化) working memory capacity (作動記憶容量) reading comprehension (読解力)
出版物タイトル 教育実践学論集
発行日 2006-03
7巻
開始ページ 41
終了ページ 50
ISSN 1345-5184
言語 英語
論文のバージョン publisher
著者 桐栄 恭二| 本水 昌二| 大島 光子| 小野田 稔|
発行日 1986-04-05
出版物タイトル 分析化学
35巻
4号
資料タイプ 学術雑誌論文
著者 秋庭 正典| 本水 昌二| 桐栄 恭二|
発行日 1987-09-05
出版物タイトル 分析化学
36巻
9号
資料タイプ 学術雑誌論文
著者 桑木 亨| 秋庭 正典| 大島 光子| 本水 昌二|
発行日 1987-08-05
出版物タイトル 分析化学
36巻
8号
資料タイプ 学術雑誌論文
著者 山本 幸市| 本水 昌二|
発行日 1987-06-05
出版物タイトル 分析化学
36巻
6号
資料タイプ 学術雑誌論文
著者 本水 昌二| 是近 勝彦|
発行日 1988-10-05
出版物タイトル 分析化学
37巻
10号
資料タイプ 学術雑誌論文