このエントリーをはてなブックマークに追加
ID 65754
フルテキストURL
著者
Kimura, Shuhei Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University ORCID Kaken ID
Hosokawa, Mio Morizane Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Shiode, Yusuke Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID
Matoba, Ryo Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kanzaki, Yuki Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Goto, Yasuhito Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kanenaga, Keisuke Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Suzuki, Etsuji Department of Epidemiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons researchmap
Morizane, Yuki Department of Ophthalmology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons
抄録
Purpose To identify a method for accurately measuring preoperative axial length (AL) in cases of rhegmatogenous retinal detachment (RRD).
Study design Retrospective study.
Methods This retrospective study included 83 eyes of 83 patients who underwent vitrectomy for RRD and had both preoperative and postoperative data for AL. Preoperative AL measurements for the affected eye were obtained using ultrasound (aUS-AL) and compared with those for affected and fellow eyes measured using optical biometry (aOB-AL and fOB-AL, respectively). Absolute differences between preoperative aUS-AL, aOB-AL, or fOB-AL measurements and postoperative AL (aPost-AL) were examined.
Results In the 41 eyes without macular detachment, the absolute difference between aOB-AL and aPost-AL (0.06±0.07 mm) was significantly smaller than between aUS-AL and aPost-AL (0.21±0.18 mm) and that between fOB-AL and aPost-AL (0.29±0.35 mm) (P = 0.017 and P < 0.001, respectively). In the 42 eyes with macular detachment, the absolute difference between aOB-AL and aPost-AL (1.22±2.40 mm) was significantly larger than between aUS-AL and aPost-AL (0.24±0.24 mm) and between fOB-AL and aPost-AL (0.35±0.49 mm) (P = 0.006, P = 0.016, respectively).
Conclusion The current findings suggest that aOB-AL is more accurate than aUS-AL or fOB-AL in cases of RRD without macular detachment, while aUS-AL or fOB-AL is more accurate than aOB-AL in cases with macular detachment.
キーワード
Axial length
Rhegmatogenous retinal detachment
Macular detachment
Fourier-domain optic biometry
Ultrasound
備考
This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s10384-023-01018-2
This fulltext file will be available in Aug. 2024.
発行日
2023-08-10
出版物タイトル
Japanese Journal of Ophthalmology
67巻
6号
出版者
Springer Science and Business Media LLC
開始ページ
645
終了ページ
651
ISSN
0021-5155
NCID
AA00691177
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© Japanese Ophthalmological Society 2023
論文のバージョン
author
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1007/s10384-023-01018-2
Citation
Kimura, S., Hosokawa, M.M., Shiode, Y. et al. Accuracy of ultrasound vs. Fourier-domain optic biometry for measuring preoperative axial length in cases of rhegmatogenous retinal detachment. Jpn J Ophthalmol 67, 645–651 (2023). https://doi.org/10.1007/s10384-023-01018-2