ID | 40704 |
フルテキストURL | |
タイトル(別表記) | An evaluation of utility of residual liver function prediction using dynamic SPECT
|
著者 |
田邉 正忠
香川医科大学放射線医学教室
玉井 豊理
香川医科大学放射線医学教室
日野 一郎
香川医科大学放射線医学教室
佐藤 功
香川医科大学放射線医学教室
児島 完治
香川医科大学放射線医学教室
大川 元臣
香川医科大学放射線医学教室
前場 隆志
香川医科大学第一外科学教室
田中 聰
香川医科大学第一外科学教室
|
抄録 | A method for evaluating and predicting residual liver function was devised for dynamic single photon emission computed tomography (SPECT). The ratio of residual volume to total effective liver volume, K value and predictive index using dynamic SPECT were compared with respective values using dynamic planar scintigraphy. The coefficients of correlation were 0.86 (the ratio), 0.91 (K value) and 0.88 (predictive index). The predictive index, measured by dynamic SPECT, was as useful as by dynamic planar scintigraphy. In addition, the resecting line using SPECT was more accurate than using planar scintigraphy. Dynamic SPECT was more useful than dynamic planar scintigraphy.
|
キーワード | 肝切除
SPECT
K値
肝シンチグラフィー
|
発行日 | 1989-02
|
出版物タイトル |
岡山医学会雑誌
|
出版物タイトル(別表記) | Journal of Okayama Medical Association
|
巻 | 101巻
|
号 | 1-2号
|
出版者 | 岡山医学会
|
出版者(別表記) | Okayama Medical Association
|
開始ページ | 7
|
終了ページ | 12
|
ISSN | 0030-1558
|
NCID | AN00032489
|
資料タイプ |
学術雑誌論文
|
オフィシャル URL | https://www.jstage.jst.go.jp/article/joma1947/101/1-2/101_1-2_7/_article/-char/ja/
|
関連URL | http://www.okayama-u.ac.jp/user/oma/
|
言語 |
日本語
|
著作権者 | 岡山医学会
|
論文のバージョン | publisher
|
査読 |
有り
|
Eprints Journal Name | joma
|