
検索結果 812 件
| JaLCDOI | 10.18926/11808 |
|---|---|
| タイトル(別表記) | RESOLUTION PROPERTIES OF CRT MONITORS |
| フルテキストURL | 002_081_088.pdf |
| 著者 | 竹内 知行| 吉田 彰| 東 義晴| 杉田 勝彦| 中村 伸枝| 岸 幹二| 平木 祥夫| |
| 抄録 | We have developed a new technique for measuring the modulation transfer function (MTF) of a cathode ray tube (CRT) monitor. The "nominal" MTF was measured by displaying a line image of a width of one pixel on the CRT monitor using the pattern generator. We also measured the effective pixel width. In order to obtain the "actual" MTF, the nominal MTF was divided by the sinc function which is the Fourier transform of the effective pixel width. The results indicate that the corrected MTF converges to the constant value as the effective pixel width is narrower. Thus, the actual MTFs were determined and compared in the horizontal direction for two CRT monitors. |
| キーワード | CRT Monitor Resolution Effective Pixel Width Modulation Transfer Function (MTF) |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1992-02-05 |
| 巻 | 2巻 |
| 開始ページ | 81 |
| 終了ページ | 88 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313719 |
| JaLCDOI | 10.18926/11805 |
|---|---|
| タイトル(別表記) | Dose Distributions at Standard Diagnostic X-Ray Energy |
| フルテキストURL | 002_063_071.pdf |
| 著者 | 三宅 英昭| 稲村 圭司| 中桐 義忠| 門久 繁文| 三上 泰隆| 東 義晴| 山田 俊治| 杉田 勝彦| 平木 祥夫| |
| 抄録 | Exposure dose has been indicated by surface dose or transit dose, but they could not indicate dose distributions inside the body. Modulex as the radiation therapy planning system was used for dose distributions at standard diagnostic X-ray energy. X-ray is low energy X-ray at standard diagnostic radiography, so alterations of the energy and the scattering dose distribution by absorbers are quite different from those at high energy X-rays. Mix-DP was put to the homogeneous tissue use, then Bone equivalent phantom or Lung equivalent phanton was put to the inhomogeneous tissue use. Density correction factors for inhomogeneous phantoms were gotten by the calculation of the water equivalent thickness. In Bone the inhomogeneous correction depended strongly on the bone thickness. In Lung it was in need of one density correction factor and the scattering correction method for the decrease of the back scattering. The calculated dose distributions by Modulex agreed with measured data when each correction was carried out, and it was indicated that those data apply to inclinical situations. |
| キーワード | Exposure Dose Dose Distribution Radiation Therapy Planning System Density Correction Scattering Correction |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1992-02-05 |
| 巻 | 2巻 |
| 開始ページ | 63 |
| 終了ページ | 71 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313328 |
| JaLCDOI | 10.18926/11766 |
|---|---|
| タイトル(別表記) | Basic properies of beam flatness analyzer (THEBES 7000) |
| フルテキストURL | 007_1_023_027.pdf |
| 著者 | 中桐 義忠| 小栗 宣博| 丸山 敏則| 大川 義弘| 若狭 弘之| 永谷 伊佐雄| 東 義晴| 渋谷 光一| 後藤 佐知子| 三上 泰隆| 稲村 圭司| 森岡 泰樹| 杉田 勝彦| 平木 祥夫| |
| 抄録 | 癌の有力な治療法の1つである放射線治療はシステム全体の許容誤差が±5%と、正確な治療が要求されている。正確な線量を正確な場所に照射されなければならない。そのためには日頃から照射装置のQuality Control が重要である。Beam平坦度の測定はその中でも、重要な項目で1/6月の測定頻度が勧告されている。今回、市販のBeam Flatness Analyzer (7000型 THEBES) を使用する機会を得たので、その基礎的性能であるChamber 相互の感度のちがい、測定値の再現性、識別可能な最小線量について実験を行った。各項目とも誤差が非常に少なく、日常の使用に際してそのデータは十分信頼できるものであることがわかった。 |
| キーワード | 放射線治療 (radiation therapy) ビーム平坦度 (beam flatness) 性能評価 (valuation of property) 電子加速器 (electron accelerator) |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1996-09-30 |
| 巻 | 7巻 |
| 号 | 1号 |
| 開始ページ | 23 |
| 終了ページ | 27 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313499 |
| JaLCDOI | 10.18926/11755 |
|---|---|
| タイトル(別表記) | New Stepwedge for Bootstrap Sensitometry in Medical Radiography |
| フルテキストURL | 001_019_027.pdf |
| 著者 | 吉田 彰| 小橋 利美| 大川 義弘| 三上 泰隆| 平木 祥夫| 東 義晴| 山田 俊治| 杉田 勝彦| |
| 抄録 | A new stepwedge has been developed for bootstrap sensitometry, which is used for determining the characteristic curve of radiographic screen/film systems. Since each step of the stepwedge is separated by the lead septum, flare generated under one step will not penetrate the region of another step. The metal of the stepwedge can be changed with various materials. Characteristic curves obtained with new stepwedge bootstrap (NSB) and conventional stepwedge bootstrap (CSB) techniques were compared with those obtained for screen/film systems with inverse sqare sensitometry. The inverse square method was used as the reference standard for accuracy. The NSB method provided characteristic curves that agreed well with those obtained using the inverse square method. The slope of the curve in the CSB method was lower than that in the inverse square or NBS method, because of scatter radiation. The shape of the characteristic curve from the NSB method did not vary with the materials of step metals (aluminum and copper). The cumulative error involved when using the bootstrap method is also discussed. |
| キーワード | Stepwedge Bootstrap Characteristic curves Sensitometry Radiographic screen/film systems |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1991-03-25 |
| 巻 | 1巻 |
| 開始ページ | 19 |
| 終了ページ | 27 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313394 |
| JaLCDOI | 10.18926/11750 |
|---|---|
| タイトル(別表記) | Total Skin Electron Beam Therapy |
| フルテキストURL | 001_001_006.pdf |
| 著者 | 中桐 義忠| 稲村 圭司| 三宅 英昭| 田原 誠司| 三村 誠一| 江草 具視| 三上 泰隆| 山田 俊治| 杉田 勝彦| 平木 祥夫| |
| 抄録 | The peripherally T-cell lymphoma; Mycosis fungoides etc, has the good radiation sensitivity, and has been adapted for total skin electron beam therapy. In this study the pendular irradiation method was used for the purpose of total skin electron beam therapy in Mycosis fungoides, and physical data on the radiation field and the electron beam energy were useful clinically. |
| キーワード | 電子線全身照射法 菌状息肉症 全身性皮膚疾患 |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1991-03-25 |
| 巻 | 1巻 |
| 開始ページ | 1 |
| 終了ページ | 6 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313887 |
| JaLCDOI | 10.18926/11735 |
|---|---|
| タイトル(別表記) | Clinical application of the contrast media containing soft drinks for the X-ray examination of the stomach |
| フルテキストURL | 006_015_021.pdf |
| 著者 | 渋谷 光一| 中桐 義忠| 東 義晴| 後藤 佐知子| 丸山 敏則| 杉田 勝彦| 大倉 保彦| 夏川 浩一| 丹谷 延義| 延原 栄太朗| 森岡 泰樹| 竹田 芳弘| 平木 祥夫| |
| 抄録 | 胃X線検査の被験者を増やし、検査を円滑に行う上で造影剤である硫酸バリウム懸濁液の飲みにくさが障害の一つとなっている。これを改善する目的で、懸濁液に市販の粉末清涼飲料を混入したところ、64.2%の人が通常のものよりも飲みやすいと答えた。臨床上も造影剤の付着が悪くなったり、胃の蠕動を促進する等の問題は生じず、有用であると考えられた。 |
| キーワード | 造影剤 (contrast media) 硫酸バリウム (barium sulfate suspension) 清涼飲料 (soft drinks) 消化管検査 (barium examination) |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1996-02-29 |
| 巻 | 6巻 |
| 開始ページ | 15 |
| 終了ページ | 21 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313345 |
| JaLCDOI | 10.18926/11730 |
|---|---|
| タイトル(別表記) | Measurement of intracellular pH by flow cytometry using pH sensitive fluorescence dye, and influence of hyperthermia and amiloride derivatives on the intracellular pH |
| フルテキストURL | 006_001_005.pdf |
| 著者 | 浅海 淳一| 川崎 祥二| 黒田 昌宏| 竹田 芳弘| 平木 祥夫| |
| 抄録 | エールリッヒ腹水癌細胞とそのアドリアマイシン耐性細胞において蛍光pH指示薬2'、7'-bis-(2-carboxyethyl) carboxyfluorescein] (BCECF) の蛍光量をフローサイトメトリーで測定することによって細胞内pHの検量曲線を作成することができた。このことより、これらの細胞においてBCECFの蛍光量で細胞内pHの変化を簡易に比較できることを示唆した。さらに、温熱、Na(+)/H(+) exchanger の阻害例であるアミロライド[3,5-diamino-6-chloro-N-(diaminomethylene) pyrazinecarboxamide]、およびアミロライド誘導隊MH-12-43[N-amidino-3-amino-6-chloro-5-(N-ethyliso-propylamino) pyrazinecarboxyamide] の細胞内pHへの影響をエールリッヒ腹水癌細胞で観察した。37℃では、0.5mMアミロライド、0.05mM MH-12-43により細胞内pHは減少し、42℃処理によりさらに減少した。42℃において、0.05mM MH-12-43による細胞内pHの減少は、0.5mMアミロライドによる減少より大きかった。 |
| キーワード | BCECF 細胞内pH (Intracellular pH) フローサイトメトリー (Flow Cytometry) アミロライド (Amiloride) MH-12-43 |
| 出版物タイトル | 岡山大学医療技術短期大学部紀要 |
| 発行日 | 1996-02-29 |
| 巻 | 6巻 |
| 開始ページ | 1 |
| 終了ページ | 5 |
| ISSN | 0917-4494 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313855 |
| JaLCDOI | 10.18926/11711 |
|---|---|
| タイトル(別表記) | Approach on the simple and easy method for measurement of airborne radioactive iodine((125)I) |
| フルテキストURL | 011_1_035_039.pdf |
| 著者 | 澁谷 光一| 山岡 聖典| 永松 知洋| 川崎 祥二| 平木 祥夫| |
| 抄録 | 放射性ヨウ素((123)I,(125)I,(131)I)は飛散しやすいなどの特性があり,他の放射性核種に比べ慎重な取扱いが求められている。また,この核種の空気中濃度限度は非常に低く,濃度測定には大量の空気を吸引しなければならず,そのための装置も大掛かりとなる。このため,本研究では,活性炭ろ紙をホルダにセットし,これを注射器に取り付けた簡易な装置を考案・試作し,空気中の放射性ヨウ素濃度を簡便に測る方法について実験・検討した。その結果,まず放射性ヨウ素にNa(125)Iを用いた場合の捕集効率は44.5%であることが分かった。次に,50mℓ注射器を用いて1ℓの空気を吸引・ろ過し,Nal(Tl)ウェルタイプシンチレーションカウンタで30分間放射能を測定した場合,本装置では空気中濃度限度の2.12倍の濃度の(125)Iが測定可能であり,気体状ヨウ素の漏れを防いで捕集効率を94.3%以上に上げることができれば,空気中濃度限度まで測定可能であることが示された。このため,本法は簡便かつ安価に異常を検知する測定方法として利用できるのではないかと考えられた。 |
| キーワード | (125)I (radioactive iodine-125) 空気中濃度限定 (air concentration limit) 活性炭ろ紙 (charcoal filter) |
| 出版物タイトル | 岡山大学医学部保健学科紀要 |
| 発行日 | 2000-11-16 |
| 巻 | 11巻 |
| 号 | 1号 |
| 開始ページ | 35 |
| 終了ページ | 39 |
| ISSN | 1345-0948 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002313683 |
| 著者 | 平木 隆夫| |
|---|---|
| 発行日 | 2001-03-31 |
| 出版物タイトル | |
| 資料タイプ | 学位論文 |
| 著者 | 平木 章夫| |
|---|---|
| 発行日 | 2001-09-30 |
| 出版物タイトル | |
| 資料タイプ | 学位論文 |
| 著者 | 平木 祥夫| |
|---|---|
| 発行日 | 1968-03-31 |
| 出版物タイトル | |
| 資料タイプ | 学位論文 |
| 著者 | 平木 俊吉| |
|---|---|
| 発行日 | 1974-09-30 |
| 出版物タイトル | |
| 資料タイプ | 学位論文 |