ID | 55663 |
JaLCDOI | |
フルテキストURL | |
著者 |
Yoshimura, Yuuki
Radiological Technology, Graduate School of Health Sciences, Okayama University
Kuroda, Masahiro
Radiological Technology, Graduate School of Health Sciences, Okayama University
Sugiantoc, Irfan
Department of Oral and Maxillofacial Radiology, Okayama University
Bamgbosec, Babatunde O.
Department of Oral and Maxillofacial Radiology, Okayama University
Miyahara, Kanae
Radiological Technology, Graduate School of Health Sciences, Okayama University
Ohmura, Yuichi
Radiological Technology, Graduate School of Health Sciences, Okayama University
Kurozumi, Akira
Radiological Technology, Graduate School of Health Sciences, Okayama University
Matsushita, Toshi
Central Division of Radiology, Okayama University Hospital
Ohno, Seiichiro
Central Division of Radiology, Okayama University Hospital
Kanazawa, Susumu
Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Asaumi, Junichi
Department of Oral and Maxillofacial Radiology, Okayama University
|
抄録 | Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE’s SNR was higher than EPI’s. Using RESOLVE, the combination of
a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE’s image distortioas less than EPI’s. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10−6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10−6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.
|
キーワード | RESOLVE
bio-phantom
3 tesla MRI
apparent diffusion coefficient
diffusion-weighted imaging
|
Amo Type | Original Article
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 2018-02
|
巻 | 72巻
|
号 | 1号
|
出版者 | Okayama University Medical School
|
開始ページ | 53
|
終了ページ | 59
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2018 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID |