抄録

Computer codes developed for the A-φ, A-φ-Ω, A-Ω, T-Ω, and E-Ω methods are considered. Their accuracy, storage requirements, and CPU time are compared for linear eddy-current models. It is shown that the A-φ-Ω and T-Ω methods are preferable from the viewpoint of accuracy. The A-Ω and E-Ω methods are preferable with respect to storage and CPU time

キーワード
eddy currents
備考
Digital Object Identifier: 10.1109/20.92367
Published with permission from the copyright holder. This is the institute's copy, as published in Magnetics, IEEE Transactions on, November 1988, Volume 24, Issue 6, Pages 3159-3161.
Publisher URL:http://dx.doi.org/10.1109/20.92367
Copyright © 1988 IEEE. All rights reserved.