ID | 56167 |
JaLCDOI | |
フルテキストURL | |
著者 |
Miyahara, Kanae
Radiological Technology, Graduate School of Health Sciences, Okayama University
Kuroda, Masahiro
Radiological Technology, Graduate School of Health Sciences, Okayama University
Yoshimura, Yuuki
Radiological Technology, Graduate School of Health Sciences, Okayama University
Aoyama, Hideki
Central Division of Radiology, Okayama University Hospital
Oita, Masataka
Radiological Technology, Graduate School of Health Sciences, Okayama University
Sugianto, Irfan
Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Matsuzaki, Hidenobu
Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ihara, Hiroki
Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Katayama, Norihisa
Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Katsui, Kuniaki
Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kanazawa, Susumu
Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Asaumi, Junichi
Department of Oral and Maxillofacial Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
|
抄録 | We used image-processing software to analyze the setup errors at the skin surface position of breast cancer patients (n=66) who underwent post-operative whole breast irradiation at our hospital in 2014-2015. The sixty-six digital reconstructed radiographs (DRR) were created at the treatment planning for each patient. The lineacgraphies (n=377) were taken after the patients’ setup during radiotherapy. The lineacgraphies and DRR were superimposed at the skin surface position for each patient with the image-processing software. We measured the deviations of the isocenters for the nipple-lung (X) direction and craniocaudal (Y) direction and the deviation of the rotation angle of the XY axes between the lineacgraphy and DRR on the superimposed images. The systematic error (μ, Σ) and random error (σ) were calculated from the X and Y deviations and rotation angle deviation. The μ of X, Y, and rotation angle were 0.01 mm, −1.2 mm, and 0.05°, respectively. The Σ of X, Y, and rotation angle were 1.8 mm, 1.5 mm, and 0.9°, respectively. The σ of X, Y, and rotation angle were 2.0 mm, 1.5 mm, and 1.0°, respectively. Our analyses thus revealed that evaluations using image-processing software at the skin surface position in routine breast radiotherapy result in sufficiently small setup errors.
|
キーワード | breast cancer
radiotherapy
position verification
skin surface
image processing software
|
Amo Type | Original Article
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 2018-08
|
巻 | 72巻
|
号 | 4号
|
出版者 | Okayama University Medical School
|
開始ページ | 331
|
終了ページ | 336
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2018 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID |