ID | 65916 |
フルテキストURL | |
著者 |
Uehara, Osamu
Medical Engineering Laboratory, ALCARE CO., Ltd.
Kusuhara, Toshimasa
Department of Radiological Technology, Graduate School of Health Sciences, Okayama University
Kaken ID
publons
researchmap
Matsuzaki, Kenichi
Medical Engineering Laboratory, ALCARE CO., Ltd.
Yamamoto, Yoshitake
Okayama University
Nakamura, Takao
Department of Radiological Technology, Graduate School of Health Sciences, Okayama University
Kaken ID
publons
researchmap
|
抄録 | Deterioration of the skin barrier function causes symptoms such as allergies because various chemical substances may enter the human body. Quantitative evaluation of the thickness and water content of the stratum corneum is useful as a measure of the skin barrier function in domains such as dermatology, nursing science, and cosmetics development. The stratum corneum is responsible for most of the skin barrier function, and two factors—the thickness and water content of the stratum corneum—are thus important. In this paper, the stratum corneum is regarded as a parallel model of resistance and capacitance. From measurements of the electrical impedance of the skin, we propose a new model for simultaneous estimation of the thickness and water content of the stratum corneum conventionally measured by a confocal laser scanning microscope and a confocal Raman spectrometer, respectively, and we discuss the results of the measurements. The electrical impedance of the skin was measured using a device that we developed. The measurement began 3 seconds after the electrodes on the measurement head of the device came into contact with the skin, and parameters including the impedance, which was obtained by applying an alternating current signal at two frequencies, were measured. We measured the thickness and water content of the stratum corneum using confocal laser microscopy and confocal Raman spectroscopy, respectively; investigated the relationship of the thickness and water content of the stratum corneum with the electrical impedance of the skin; and established a new potential model for estimating the thickness and water content of the stratum corneum from the parallel resistance and capacitance. The correlation coefficients of the verification data were 0.931 and 0.776, respectively; and the root-mean-squared error of the thickness of the stratum corneum was 2.3 µm, while the root-mean-squared error of the water content at the surface of the stratum corneum was 5.4 points. These findings indicate the feasibility of quantitative evaluation of the thickness and water content of the stratum corneum by measuring skin electrical impedance.
|
キーワード | skin electrical impedance
thickness
water content
stratum corneum
skin barrier
|
発行日 | 2022
|
出版物タイトル |
Advanced Biomedical Engineering
|
巻 | 11巻
|
出版者 | Japanese Society for Medical and Biological Engineering
|
開始ページ | 98
|
終了ページ | 108
|
ISSN | 2187-5219
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
OAI-PMH Set |
岡山大学
|
著作権者 | ©2022 The Author(s).
|
論文のバージョン | publisher
|
DOI | |
Web of Science KeyUT | |
関連URL | isVersionOf https://doi.org/10.14326/abe.11.98
|
ライセンス | https://creativecommons.org/licenses/by/4.0/
|