このエントリーをはてなブックマークに追加


ID 66673
JaLCDOI
フルテキストURL
78_1_071.pdf 2.38 MB
著者
Kaneda, Daisuke Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nishida, Keiichiro Locomotive Pain Center, Okayama University Hospital Kaken ID publons researchmap
Nasu, Yoshihisa Department of Orthopaedic Surgery, Okayama University Hospital
Nakahara, Ryuichi Department of Orthopaedic Surgery, Okayama University Hospital
Harada, Ryozo Department of Orthopaedic Surgery, Kurashiki Sweet Hospital
Hotta, Yoshifumi Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Naniwa, Shuichi Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
抄録
We retrospectively investigated the mid-term outcomes of arthroplasty using the AVANTA silicone implant for thumb metacarpophalangeal (MCP) joints with boutonniere deformity in patients with rheumatoid arthritis (RA). This study involved 36 thumbs of 33 RA patients with a mean follow-up period of 5.1 years (range, 2.0-13.3). Postoperatively, the mean extension was significantly increased and the mean flexion was significantly decreased (p<0.001, p<0.001, respectively), resulting in the mean arc of range of motion (ROM) shifting in the direction of extension after surgery. Implant fracture was observed in 10 thumbs (28%), and 4 of these (11%) underwent revision surgery. The survivorship with implant fracture and revision surgery as endpoints were 73.4% and 91.8% at 5 years, respectively. The preoperative arc of ROM and the postoperative flexion range of the implant-fracture group were significantly greater than those in the no-implant-fracture group (p=0.039, 0.034, respectively). These results suggest the importance of patient education and careful rehabilitation to prevent excessive flexion. Overall, the AVANTA silicone implant showed a relatively high rate of implant fracture at our institute.
キーワード
AVANTA silicone implant
boutonniere deformity
implant fracture
thumb metacarpophalangeal joint arthroplasty
rheumatoid arthritis
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2024-02
78巻
1号
出版者
Okayama University Medical School
開始ページ
71
終了ページ
78
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
著作権者
Copyright Ⓒ 2024 by Okayama University Medical School
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT