このエントリーをはてなブックマークに追加


ID 60880
JaLCDOI
フルテキストURL
74_6_505.pdf 7.82 MB
著者
Ohara, Toshiaki Department of Pathology & Experimental Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID Kaken ID publons researchmap
Sakurama, Kazufumi Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Hiramatsu, Satoshi Department of Dialysis Access Center, Shigei Medical Research Hospital
抄録
Vascular-access interventions are necessary for the continuation of hemodialysis, and they are performed under X-ray guidance. During interventions, patients’ accidental falls from the bed are a serious problem, and spe-cialized fixation systems for hemodialysis patients to prevent their falls from the bed have been lacking. We developed a new fixation plate made of polypropylene homopolymer and tested its ability to prevent such falls retrospectively. This plate, which we named the ‘vascular-access intervention assistance plate,’ offers functional features such as the concurrent fixation of the body and either arm and an arm space with serrations for fixing a forearm strap. We performed computer simulations to examine the strength of the plate, and we evaluated the efficacy of fall prevention by reviewing patients’ medical records. The results demonstrated that the functional design of the plate provides good operability via accurate concurrent fixations of the body and arm. The com-puter simulation analysis results indicated the plate’s sufficient strength. The medical records analysis revealed three accidental falls before the plate’s introduction (401 patients, 1,437 interventions), and none after plate introduction (683 patients, 1,872 interventions). Accidental falls were significantly prevented by use of the plate (p < 0.05). The dementia rate and type of procedure were not significantly different between the patients who fell and those who did not. This vascular-access intervention assisted plate provides good operability and safety by preventing accidental falls among hemodialysis patients.
キーワード
hemodialysis
fall accident
incident
vascular access
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2020-12
74巻
6号
出版者
Okayama University Medical School
開始ページ
505
終了ページ
511
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
著作権者
CopyrightⒸ 2020 by Okayama University Medical School
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT
NAID
助成番号
Hashida M and Shiraishi J: Incident reports related to tasks per-formed by radiological technologists: an analysis of ten years of incident reports. Nihon Hoshasen Gijutsu Gakkai Zasshi (2015) 71: 99-107.