このエントリーをはてなブックマークに追加
ID 61277
フルテキストURL
著者
Komaki, Toshiyuki Department of Radiology, Okayama University Medical School
Hiraki, Takao Department of Radiology, Okayama University Medical School
Kamegawa, Tetsushi Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University Kaken ID publons researchmap
Matsuno, Takayuki Graduate School of Natural Science and Technology, Okayama University
Sakurai, Jun Center for Innovative Clinical Medicine, Okayama University Hospital
Matsuura, Ryutaro Graduate School of Health Sciences, Okayama University Medical School
Yamaguchi, Takuya Division of Radiology, Department of Medical Technology, Okayama University Hospital
Sasaki, Takanori Collaborative Research Center for OMIC, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences Kaken ID researchmap
Mitsuhashi, Toshiharu Center for Innovative Clinical Medicine, Okayama University Hospital Kaken ID researchmap
Okamoto, Soichiro Department of Radiology, Okayama University Medical School
Uka, Mayu Department of Radiology, Okayama University Medical School
Matsui, Yusuke Department of Radiology, Okayama University Medical School
Iguchi, Toshihiro Department of Radiology, Okayama University Medical School
Gobara, Hideo Division of Medical Informatics, Okayama University Hospital ORCID Kaken ID publons researchmap
Kanazawa, Susumu Department of Radiology, Okayama University Medical School Kaken ID publons
抄録
Objectives
To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments.
Methods
A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student’s t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center.
Results
In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively.
Conclusion
Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion.
キーワード
Robotics
Interventional radiology
Animal experiments
発行日
2019-11-26
出版物タイトル
European Radiology
30巻
3号
出版者
Springer
開始ページ
1342
終了ページ
1349
ISSN
0938-7994
NCID
AA10824302
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© Authors
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1007/s00330-019-06477-1
ライセンス
http://creativecommons.org/licenses/by/4.0/
助成機関名
日本学術振興会
Japan Agency for Medical Research and Development
助成番号
17K10439
25461882
18K07677
15hk0102014h001
15hk0102014h002
15hk0102014h003