このエントリーをはてなブックマークに追加
ID 69742
フルテキストURL
fulltext.pdf 1.71 MB
著者
Masada, Yasutaka Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Tetsunaga, Tomonori Department of Musculoskeletal Health Promotion, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University ORCID Kaken ID
Yamada, Kazuki Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Koura, Takashi Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Inoue, Tomohiro Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Okuda, Ryuichiro Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Tetsunaga, Tomoko Department of Orthopaedic Surgery, Okayama University Hospital
Yokoyama, Yusuke Department of Orthopaedic Surgery, Okayama University Hospital
Okazaki, Yuki Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Ozaki, Toshifumi Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons researchmap
抄録
Introduction
Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.
Patients and methods
We retrospectively analyzed data from 80 patients (14 male and 66 female, mean age: 65 ± 8.4 years) who underwent primary THA using Actis stems (anterolateral approach, 60 hips; posterior approach, 20 hips). Radiographs were obtained postoperatively and at the time of the final examination. Radiographic assessments included the alignment of the femoral stem, spot welds, stress shielding, cortical hypertrophy, subsidence (>2 mm), radiolucent line, pedestal formation, Dorr type, canal fill ratio (CFR), and stem fixation. Clinical evaluation included the Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ) and Harris Hip Score (HHS).
Results
The mean follow-up period was 64.0 ± 6.0 months. No significant differences were observed in the alignment of the femoral components between approaches. Of the 80 hips, 53 (66.3%) showed radiographic signs of stem osseointegration, predominantly in the mid-distal region of the stem at the final follow-up. Multiple logistic regression analysis revealed that younger age and a higher CFR (20 mm proximal to the lesser trochanter) were associated with the presence of spot welds. Mild stress shielding occurred in 25 hips (31.3%), and no patient experienced severe stress shielding. All stems were fixed by bone on growth. The JHEQ and HHS significantly improved at the final assessment.
Conclusion
At the five-year follow-up, patients who received the Actis Total Hip System during THA had good radiographic and clinical outcomes.
キーワード
actis
hydroxyapatite
mid-term outcome
spot welds
stem
total hip arthroplasty
発行日
2025-01-18
出版物タイトル
Cureus
17巻
1号
出版者
Springer Science and Business Media LLC
開始ページ
e77632
ISSN
2168-8184
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© Copyright 2025 Masada et al.
論文のバージョン
publisher
PubMed ID
DOI
関連URL
isVersionOf https://doi.org/10.7759/cureus.77632
ライセンス
https://creativecommons.org/licenses/by/4.0/
Citation
Masada Y, Tetsunaga T, Yamada K, et al. (January 18, 2025) Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study. Cureus 17(1): e77632. doi:10.7759/cureus.77632