Higaki, Fumiyo Department of Radiology, Okayama University Hospital
Morimitsu, Yusuke Department of Radiological Technology, Okayama University Hospital
Iguchi, Toshihiro Department of Radiological Technology, Faculty of Health Sciences, Okayama University Kaken ID
Saito, Hayato Department of Radiological Technology, Okayama University Medical School
Takaki, Haruhiko Department of Radiological Technology, Okayama University Medical School
Nakagoshi, Ayako Department of Radiological Technology, Okayama University Medical School
Wada, Maki Department of Radiological Technology, Okayama University Medical School
Uka, Mayu Department of Radiology, Okayama University Hospital
Akagi, Noriaki Department of Radiological Technology, Okayama University Hospital
Mitsuhashi, Toshiharu Center for Innovative Clinical Medicine, Okayama University Hospital Kaken ID researchmap
Matsui, Yusuke Department of Radiology, Okayama University Faculty of Medicine, Dentistry and Pharmaceutical Sciences
Hiraki, Takao Department of Radiology, Okayama University Faculty of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
抄録
This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.
キーワード
photon-counting detector CT
energy integrating detector CT
computed tomography
contrast medium amount
reduction
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2024-04
78巻
2号
出版者
Okayama University Medical School
開始ページ
135
終了ページ
142
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
著作権者
Copyright Ⓒ 2024 by Okayama University Medical School
論文のバージョン
publisher
査読
有り