このエントリーをはてなブックマークに追加
ID 62817
JaLCDOI
フルテキストURL
著者
Endo, Hirosuke Department of Bone and Joint Surgery, Kawasaki Medical School, Kurashiki City
Yamada, Kazuki Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Denstry and Pharmaceutical Scineces
Testunaga, Tomonori Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Denstry and Pharmaceutical Scineces
Furumatsu, Takayuki Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Denstry and Pharmaceutical Scineces Kaken ID publons
Mitani, Shigeru Department of Bone and Joint Surgery, Kawasaki Medical School, Kurashiki City
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Denstry and Pharmaceutical Scineces Kaken ID publons researchmap
抄録
The improved cemented cup technique has attained excellent long-term results in primary total hip arthroplasty. When cup revision surgery was performed, the cemented cup, which was loosened at the bone-cement interface, was easily removed. However, with a well-fixed bone-cement interface, it remains difficult to remove the cemented cup for a revision in the event of a recurring dislocation. In addition, protrusions in the cement can cause unpredictable bone defects. A new removal device was created and used successfully to remove a well-fixed cemented cup safely and efficiently. This report introduces the device and the technique used in cemented cup removal.
キーワード
total hip arthroplasty
revision surgery
well-fixed
cemented cup
Amo Type
Case Report
出版物タイトル
Acta Medica Okayama
発行日
2021-12
75巻
6号
出版者
Okayama University Medical School
開始ページ
751
終了ページ
754
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
著作権者
Copyright Ⓒ 2021 by Okayama University Medical School
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT
NAID