抄録
This paper describes a new measurement method and principle of detection of biodynamics using bioelectrical impedance method based on four-electrode technique with sinusoidal constant current. This method uses a human body itself as a part of the sensor. First, we show a bioelectrical impedance measuring device and the change of bioelectrical resistance is measured in human movement. Second, we proposes a principle of detection of biodynamics based on correspondence of magnitude, form and stability of movement to impedance waveform. Hence we can use this method for the judgement of sports skill using the impedance characteristics.