このエントリーをはてなブックマークに追加
ID 15390
JaLCDOI
Sort Key
3
フルテキストURL
著者
Hirashima Masao Mitsui. Metal Engineering &Service Co., Ltd.
稲葉 英男 Department of Mechanical Engineering
抄録
Heating and refrigerating technique such as snow melting of road and cold storage by utilizing temperature difference between underground soil and atmosphere is widely used[1-4] in a cold area. In the 1st Report, heat transfer characteristics of two phase closed thermosiphon for extracting geothermal energy is studied fundamentally. In the empirical study, heat extract rate is measured in connection with the change of atmospheric temperature utilizing real two thermosiphons on the site. Temperature distribution on the surface of the thermosiphon and underground soil around it is also measured. Based on the data of the empirical experiment, it is confirmed that prevention of freezing for fire hydrant can be achieved by geothermal heat utilizing two phase closed thermosiphon. Present paper describes the heat transfer behavior of the thermosiphon as the 2nd report.
出版物タイトル
Memoirs of the Faculty of Engineering, Okayama University
発行日
1992-11-25
27巻
1号
出版者
Faculty of Engineering, Okayama University
出版者(別表記)
岡山大学工学部
開始ページ
27
終了ページ
32
ISSN
0475-0071
NCID
AA10699856
資料タイプ
紀要論文
OAI-PMH Set
岡山大学
言語
英語
論文のバージョン
publisher
NAID
Eprints Journal Name
mfe