ID | 61033 |
フルテキストURL | |
著者 |
Iwamuro, Masaya
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
researchmap
Takahashi, Takahide
Division of Medical Support, Okayama University Hospital
Watanabe, Natsuki
Division of Medical Support, Okayama University Hospital
Omote, Sizuma
Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Matsueda, Katsunori
Department of Gastrointestinal Oncology, Osaka International Cancer Institute
Tanaka, Takehiro
Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
Ennishi, Daisuke
Department of Hematology and Oncology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Otsuka, Fumio
Department of General Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
researchmap
Yoshino, Tadashi
Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
researchmap
Okada, Hiroyuki
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
researchmap
|
抄録 | In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility: 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa.
|
キーワード | Flow cytometry
Light chain restriction
Gastrointestinal lymphoma
Lymphocyte isolation
|
発行日 | 2020
|
出版物タイトル |
MethodsX
|
巻 | 7巻
|
出版者 | Elsevier
|
開始ページ | 101095
|
ISSN | 2215-0161
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
OAI-PMH Set |
岡山大学
|
著作権者 | © 2020 The Author(s).
|
論文のバージョン | publisher
|
PubMed ID | |
DOI | |
Web of Science KeyUT | |
関連URL | isVersionOf https://doi.org/10.1016/j.mex.2020.101095
|
ライセンス | http://creativecommons.org/licenses/by/4.0/
|