このエントリーをはてなブックマークに追加
ID 65914
フルテキストURL
著者
Yamane, Takahiro Department of Biomedical Informatics, Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Hirano, Kazuya Department of Biomedical Informatics, Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Hirai, Kenta Department of Pediatrics, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Ousaka, Daiki Department of Pharmacology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Sakano, Noriko Department of Cardiovascular Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science Kaken ID
Morita, Mizuki Department of Biomedical Informatics, Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Oozawa, Susumu Department of Clinical Safety, Okayama University Hospital
Kasahara, Shingo Department of Cardiovascular Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science Kaken ID publons
抄録
Cardiac arrest has been reported during participation in several sports. Of these sports, marathon running is a particularly popular sport but imposes high cardiac load. Indeed, its popularity has been growing worldwide. Risk of cardiac arrest during marathon races is also expected to increase. Several studies have recorded electrocardiographic (ECG) information during marathon races to protect athletes from cardiac arrest. Although evaluable ECG data have been obtained and analyzed, cost-effectiveness of the system, data quality, and clinical significance remain inadequate. This report is the first to describe an economical electrocardiograph built into a T-shirt for use during marathon race. Twenty healthy runners aged 20 to 59 years (mean 36 years) wore the ECG device while running. The ECG data were monitored and analyzed to assess the observed frequencies of specified arrhythmias and the sections of the marathon in which the arrhythmias occurred. Of the ECG data obtained from 14 runners who completed the full marathon, six ECG datasets were evaluable. In some runners, there was inadequate contact between the electrode and body surface or poor Bluetooth connection between the ECG wireless transmitter and smartphone. Regarding arrhythmia analysis, all evaluable data that were analyzed showed some rhythm fluctuations. In conclusion, this economical T-shirt type ECG sensor provided evaluable ECG data during marathon races, although the evaluable rate was not high. The data were used to analyze specified arrhythmias, but some difficulties were encountered. The ECG sensor did not function properly because of a system error. The ECG sensor was not adequately moistened to record ECGs accurately. Moreover, some runners chose an unsuitable shirt size, which impaired the stability and strength of the electrode–skin contact. These shortcomings produced noise in the ECG data, which made it difficult to analyze arrhythmias. The next step will be to solve these problems and acquire data from a large number of runners.
キーワード
electrocardiogram
distance running
prevention
sudden cardiac arrest
T-shirt type sensor
発行日
2022
出版物タイトル
Advanced Biomedical Engineering
11巻
出版者
Japanese Society for Medical and Biological Engineering
開始ページ
151
終了ページ
161
ISSN
2187-5219
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
©2022 The Author(s).
論文のバージョン
publisher
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.14326/abe.11.151
ライセンス
https://creativecommons.org/licenses/by/4.0/