このエントリーをはてなブックマークに追加
ID 32855
JaLCDOI
フルテキストURL
fulltext.pdf 2.05 MB
著者
Shimamura, Yasunori Departments of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons
Nishida, Keiichiro Departments of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
Imatani, Junya Department of Orthopaedic Surgery, Okayama Saiseikai General Hospital
Noda, Tomoyuki Departments of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID Kaken ID publons
Hashizume, Hiroyuki Department of Orthopaedic Surgery, Kasaoka Daiichi Hospital
Ohtsuka, Aiji Human Morphology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
Ozaki, Toshifumi Departments of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
抄録

We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.

キーワード
distal humerus
fracture
biomechanics
internal fixation
elderly
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2010-04
64巻
2号
出版者
Okayama University Medical School
開始ページ
115
終了ページ
120
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT