このエントリーをはてなブックマークに追加
ID 56915
フルテキストURL
著者
Zhou, Xiaoyu The Pheasant Memorial Laboratory for Geochemistry and Cosmochemistry, Institute for Planetary Materials, Okayama University ORCID
Tanaka, Ryoji The Pheasant Memorial Laboratory for Geochemistry and Cosmochemistry, Institute for Planetary Materials, Okayama University ORCID Kaken ID publons researchmap
Yamanaka, Masahiro The Pheasant Memorial Laboratory for Geochemistry and Cosmochemistry, Institute for Planetary Materials, Okayama University
Sakaguchi, Chie The Pheasant Memorial Laboratory for Geochemistry and Cosmochemistry, Institute for Planetary Materials, Okayama University publons
Nakamura, Eizo The Pheasant Memorial Laboratory for Geochemistry and Cosmochemistry, Institute for Planetary Materials, Okayama University Kaken ID publons researchmap
抄録
Sample decomposition using inverse aqua regia at elevated temperatures and pressures (e.g., Carius tube or high‐pressure asher) is the most common method used to extract highly siderophile elements (HSEs: Ru, Rh, Pd, Re, Os, Ir, Pt and Au) from geological samples. Recently, it has been recognised that additional HF desilicification is necessary to better recover HSEs, potentially contained within silicate or oxide minerals in mafic samples, which cannot be dissolved solely by inverse aqua regia. However, the abundance of interfering elements tends to increase in the eluent when conventional ion‐exchange purification procedures are applied to desilicified samples. In this study, we developed an improved purification method to determine HSEs in desilicified samples. This method enables the reduction of the ratios of isobaric and polyatomic interferences, relative to the measured intensities of HSE isotope masses, to less than a few hundred parts per million. Furthermore, the total procedural blanks are either comparable to or lower than conventional methods. Thus, this method allows accurate and precise HSE measurements in mafic and ultramafic geological samples, without the need for interference corrections. Moreover, the problem of increased interfering elements, such as Zr for Pd and Cr for Ru, is circumvented for the desilicified samples.
キーワード
highly siderophile elements
desilicification
isotope dilution method
high resolution ICP-MS
N-TIMS
発行日
2019-03-20
出版物タイトル
Geostandards and Geoanalytical Research
43巻
4号
出版者
John Wiley
開始ページ
611
終了ページ
633
ISSN
16394488
NCID
AA11984494
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
論文のバージョン
author
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1111/ggr.12280
ライセンス
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
助成機関名
日本学術振興会
助成番号
16K05578