抄録
Fenestration has been reported to enhance Fontan hemodynamics in several cases of Fontan circulation. However, the indication criteria for fenestration remain under discussion. To assess the effectiveness of fenestration in Fontan circulation, we conducted a theoretical analysis using a computational model of the fenestrated Fontan circulation. The cardiac chambers and vascular systems were modeled using the time-varying elastance model and the modified Windkessel model, respectively. When the pulmonary vascular resistance index was 4.01 Wood units m2, fenestration significantly reduced central venous pressure from 18.0 to 16.1 mmHg and decreased stressed blood volume from 610 to 555 ml. However, in the models with reduced ventricular end-systolic elastance, increased ventricular stiffness constant, or heightened systemic vascular resistance, the advantages of fenestration were diminished. Thus, fenestration may effectively improve the hemodynamics of Fontan circulation in patients with elevated pulmonary vascular resistance.
キーワード
Single ventricle
Fontan circulation
Fenestration
Hemodynamic simulation
Lumped parameter model
備考
The version of record of this article, first published in The Journal of Physiological Sciences, is available online at Publisher’s website: http://dx.doi.org/10.1186/s12576-024-00947-y
発行日
2024-12-21
出版物タイトル
The Journal of Physiological Sciences
74巻
1号
出版者
BMC
開始ページ
58
ISSN
1880-6546
NCID
AA12129145
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© The Author(s) 2024.
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1186/s12576-024-00947-y
ライセンス
http://creativecommons.org/licenses/by/4.0/
Citation
Horio, N., Shimizu, S., Kotani, Y. et al. Evaluation of the effects of fenestration in Fontan circulation using a lumped parameter model. J Physiol Sci 74, 58 (2024). https://doi.org/10.1186/s12576-024-00947-y
助成機関名
Japan Society for the Promotion of Science
Miyata foundation
助成番号
JP22K12794