このエントリーをはてなブックマークに追加
ID 30972
JaLCDOI
フルテキストURL
fulltext.pdf 6.65 MB
著者
Endo, Hirosuke Department of Orthopaedic Surgery, Okayama University Hospital
Asaumi, Koji Department of Orthopaedic Surgery, Okayama Red Cross Hospital
Mitani, Shigeru Department of Orthopaedic Surgery, Okayama University Hospital
Noda, Tomoyuki Department of Orthopaedic Surgery, Okayama University Hospital ORCID Kaken ID publons
Minagawa, Hiroshi Department of Orthopaedic Surgery, Okayama University Hospital
Tetsunaga, Tomonori Department of Orthopaedic Surgery, Okayama University Hospital
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Hospital Kaken ID publons researchmap
抄録

A minimally invasive plate osteosynthesis technique using a locking compression plate (LCP) has been used widely in trauma cases. Its advantages are that the MIPO technique does not interfere with the fracture site and thus provides improved biological healing, and that the LCP has excellent angular stability. Its use in bone lengthening, however, has not been established. In such cases, it is desirable to shorten the external skeletal fixation period as much as possible. Here, the MIPO technique using an LCP was applied to femoral distraction osteogenesis in an attempt to shorten the external skeletal fixation period. For femoral lengthening, the MIPO technique was performed in 2 stages. Orthofix external fixators (Orthofix, England) were used to insert screws from the anterolateral side rather than from the lateral side of the femur for bone lengthening. When sufficient callus formation was detected postoperatively at the site of bone lengthening, and the absence of infection was ensured, limb draping was performed, including a whole external fixator, and then the MIPO technique was applied with an LCP. In 3 cases (5 limbs), the average duration of external skeletal fixation was 134days, the average external-fixation index was 24days/cm, and the average consolidation index was 22days/cm. The MIPO technique using an LCP made it possible to shorten the external skeletal fixation-wearing period in femoral lengthening.

キーワード
femoral lengthening
minimally invasive plate osteosynthesis
locking compression plate
external skeletal fixation
external-fixation index
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2008-10
62巻
5号
出版者
Okayama University Medical School
開始ページ
333
終了ページ
339
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT