著者 Nishida, Keiichiro| Hashizume, Kenzo| Ozawa, Masatsugu| Takeshita, Ayumu| Kaneda, Daisuke| Nakahara, Ryuichi| Nasu, Yoshihisa| Shimamura, Yasunori| Inoue, Hajime| Ozaki, Toshifumi|
発行日 2017-02
出版物タイトル Acta Medica Okayama
71巻
1号
資料タイプ 学術雑誌論文
JaLCDOI 10.18926/AMO/51867
フルテキストURL 67_5_311.pdf
著者 Nishida, Keiichiro| Hashizume, Hiroyuki| Matsukawa, Akihiro| Hashizume, Kenzo| Shimamura, Yasunori| Torigoe, Yasuyuki| Ozaki, Toshifumi|
抄録 We report a case of 4th metacarpal head collapse of a 19-year-old healthy man. MRI revealed T1 low and T2 high regions in the collapsed 4th metacarpal head, as well as in the right 3rd and left 4th metacarpal head. Our initial diagnosis was occult compression fracture due to avascular necrosis, known as Dieterich's disease. However, pathological findings of surgically resected right 4th metacarpal head were compatible with transient osteoporosis and metacarpal head fracture followed by active tissue repair. The autologous osteochondral transplants from costchondral junction survived and maintained their size and shape even at 10-year follow-up.
キーワード occult compression fracture metacarpal head avascular necrosis osteochondral autograft
Amo Type Case Report
発行日 2013-10
出版物タイトル Acta Medica Okayama
67巻
5号
出版者 Okayama University Medical School
開始ページ 311
終了ページ 317
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
OAI-PMH Set 岡山大学
著作権者 CopyrightⒸ 2013 by Okayama University Medical School
論文のバージョン publisher
査読 有り
Submission Path amo/vol67/iss5/5
PubMed ID 24145731
Web of Sience KeyUT 000325836100005
著者 島村 安則| 井上 円加| 小澤 正嗣| 金澤 智子| 斎藤 太一| 中原 龍一| 野田 知之| 西田 圭一郎| 尾﨑 敏文|
発行日 2011-08-01
出版物タイトル 岡山医学会雑誌
123巻
2号
資料タイプ 学術雑誌論文
JaLCDOI 10.18926/AMO/32855
フルテキストURL fulltext.pdf
著者 Shimamura, Yasunori| Nishida, Keiichiro| Imatani, Junya| Noda, Tomoyuki| Hashizume, Hiroyuki| Ohtsuka, Aiji| Ozaki, Toshifumi|
抄録 <p>We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.</p>
キーワード distal humerus fracture biomechanics internal fixation elderly
Amo Type Original Article
発行日 2010-04
出版物タイトル Acta Medica Okayama
64巻
2号
出版者 Okayama University Medical School
開始ページ 115
終了ページ 120
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
OAI-PMH Set 岡山大学
論文のバージョン publisher
査読 有り
Submission Path amo/vol64/iss2/5
PubMed ID 20424666
Web of Sience KeyUT 000276996900005