The basic study on measuring method of contamination of the ground and the effective porosity by using dielectric constant measuring system
著者
西垣 誠 岡山大学環境理工学部 Kaken ID publons researchmap
小松 満 岡山大学大学院自然科学研究科 ORCID Kaken ID publons researchmap
金 萬鎰 岡山大学大学院自然科学研究科
抄録
For evaluating subsurface contamination, sampling method (boring) is commonly used, but this method cannot monitor the change of in-situ contamination and concentration with respect to time. The purpose of this study is to develop a measuring system for subsurface contamination in which a so-called FDR (Frequency Domain Refiectometry) and FDR-V (with Vector network analyzer) system was employed to measure the salinity and oil contaminant. This FDR and FDR-V method is a coaxial probe method, which allows the measurement of the dielectric. The experimental study indicates the possibility in measuring both the contaminant concentration and volumetric moisture content. In addition, the method for obtaining the effective porosity using this equipment was shown. Concretely, the sensor was inserted in the ground, and the liquid in which the dielectric constant differed on the water in the circumference was injected, and the method for obtaining the effective porosity from the change of the dielectric constant was proposed.
キーワード
Dielectric constant
Contamination
Frequency Domain Refiectometry
In-situ
Effective porosity
備考
論文
発行日
2003-08
出版物タイトル
環境制御
出版物タイトル(別表記)
Environmental Research and Control
25巻
出版者
岡山大学環境管理センター
出版者(別表記)
Okayama University Administration Center for Environmental Science and Technology
開始ページ
19
終了ページ
24