このエントリーをはてなブックマークに追加
ID 57947
JaLCDOI
フルテキストURL
74_1_7.pdf 3.41 MB
著者
Sanki, Tomoaki Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Endo, Hirosuke Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons
Tetsunaga, Tomonori Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID Kaken ID
Furumatsu, Takayuki Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons
Yamada, Kazuki Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
抄録
We investigated the relationship between the initial contact status and stress shielding in total hip arthroplasty (THA) using fit-and-fill type straight-stem implants. In addition we evaluated the clinical and radiographic outcomes. Subjects were 100 hips of 94 patients who underwent THA and were followed-up for ≥10 years. Contact areas with the femoral cortical bone were investigated according to the zonal distribution of Gruen using postoperative CT images. Depending on the number of contact areas, the patients were classified into high contact [HC], medium contact [MC], and low contact [LC] groups. Radiographic and clinical outcomes were evaluated. In the HC group (20 hips), severe stress shielding was observed in 12 hips, which was statistically significant (p=0.008). In the LC group (29 hips), mild stress shielding was observed in 27 hips which was statistically significant (p<0.001). No significant differences were observed among the 3 groups in clinical outcomes, Harris hip score (p=0.719) or Japanese Orthopedic Association (JOA) score (p=0.301). In insertion of cementless collared fit-and-fill type straight-stem implants, severe late stress shielding of the femoral bone may occur if high contact of the femoral component is achieved. However, the degree of stress shielding does not result in adverse clinical outcomes.
キーワード
fit-and-fill
stress shielding
cementless straight stem
total hip arthroplasty
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2020-02
74巻
1号
出版者
Okayama University Medical School
開始ページ
7
終了ページ
15
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
著作権者
CopyrightⒸ 2020 by Okayama University Medical School
論文のバージョン
publisher
査読
有り
PubMed ID
Web of Science KeyUT
NAID