このエントリーをはてなブックマークに追加
ID 66911
フルテキストURL
fulltext.pdf 1.31 MB
著者
Takahashi, Yuka Department of Radiology, Okayama University Hospital
Higaki, Fumiyo Department of Radiology, Okayama University Hospital
Sugaya, Akiko Department of Otolaryngology‑Head and Neck Surgery, Okayama University Hospital Kaken ID researchmap
Asano, Yudai Department of Radiology, Okayama University Hospital
Kojima, Katsuhide Department of Radiology, Okayama University Hospital
Morimitsu, Yusuke Department of Radiological Technology, Okayama University Hospital
Akagi, Noriaki Department of Radiological Technology, Okayama University Hospital
Itoh, Toshihide Department of CT‑Research and Collaboration, Siemens Healthineers
Matsui, Yusuke Department of Radiology, Okayama University Faculty of Medicine, Dentistry, and Pharmaceutical Sciences
Hiraki, Takao Department of Radiology, Okayama University Faculty of Medicine, Dentistry, and Pharmaceutical Sciences Kaken ID publons researchmap
抄録
Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.
キーワード
Photon-counting detector computed tomography
Energy-integrating detectors
Ear ossicles
High-resolution imaging
3D
備考
The version of record of this article, first published in Japanese Journal of Radiology, is available online at Publisher’s website: http://dx.doi.org/10.1007/s11604-023-01485-0
発行日
2023-08-27
出版物タイトル
Japanese Journal of Radiology
42巻
2号
出版者
Springer Science and Business Media LLC
開始ページ
158
終了ページ
164
ISSN
1867-1071
NCID
AA12375935
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© The Author(s) 2023
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1007/s11604-023-01485-0
ライセンス
http://creativecommons.org/licenses/by/4.0/
Citation
Takahashi, Y., Higaki, F., Sugaya, A. et al. Evaluation of the ear ossicles with photon-counting detector CT. Jpn J Radiol 42, 158–164 (2024). https://doi.org/10.1007/s11604-023-01485-0