このエントリーをはてなブックマークに追加
ID 69219
フルテキストURL
著者
Shimooka, So Faculty of Environmental, Life, Natural Science and Technology, Okayama University
Yokoya, Hirosato Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Hamada, Masanori Department of Rehabilitation Medicine, Okayama University Hospital
Shiomi, Shun Department of Rehabilitation Medicine, Okayama University Hospital
Uehara, Takenori Department of Orthopaedic Surgery, NHO Okayama Medical Center
Hirayama, Takahiro Department of Emergency, Critical Care and Disaster Medicine, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kamegawa, Tetsushi Faculty of Environmental, Life, Natural Science and Technology, Okayama University Kaken ID publons researchmap
抄録
Nowadays, owing to declining birthrates and an aging population, patients and the elderly requiring rehabilitation are not getting enough physical activity. In addressing this issue, devices for rehabilitating them have been researched and developed. However, rehabilitation devices are almost exclusively used for patients who can get up, rather than those who are bedridden. In this study, we aim to develop a rehabilitation device that can provide passive exercise for bedridden patients. The ankle joint was selected as the target joint because the patients who have undergone surgery for cerebrovascular disease remain bedridden, and early recovery in the acute stage is highly desirable. We proposed and tested a fan-shaped pneumatic soft actuator (FPSA) that can expand and bend stably at angles when supply pressure is applied as an actuator for a rehabilitation device to encourage patient exercise. However, the previous FPSA’s movement deviates from the arch of the foot owing to increased supply pressure. In the ideal case, FPSA should push the arch of the foot in an arc motion. This study proposes and tests the FPSA that can operate a bending motion to provide passive exercise to the ankle joint using tensile springs and a winding mechanism powered by a servo motor. The proposed FPSA has a significant advantage of exhibiting no hysteresis in its pressure-displacement characteristics. The configuration and static analytical model of the improved FPSA are described.
キーワード
fan-shaped pneumatic soft actuator
ankle-joint rehabilitation device
hysteresis
range of motion
発行日
2025-02-20
出版物タイトル
Journal of Robotics and Mechatronics
37巻
1号
出版者
Fuji Technology Press Ltd.
開始ページ
43
終了ページ
53
ISSN
1883-8049
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© Fuji Technology Press Ltd.
論文のバージョン
publisher
DOI
CRID
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.20965/jrm.2025.p0043
ライセンス
https://creativecommons.org/licenses/by-nd/4.0/
Citation
S. Shimooka, H. Yokoya, M. Hamada, S. Shiomi, T. Uehara, T. Hirayama, and T. Kamegawa, “Fan-Shaped Pneumatic Soft Actuator that Can Operate Bending Motion for Ankle-Joint Rehabilitation Device,” J. Robot. Mechatron., Vol.37 No.1, pp. 43-53, 2025.
助成情報
( Hashimoto Foundation )