このエントリーをはてなブックマークに追加
ID 30731
JaLCDOI
フルテキストURL
著者
Mukai, Takashi Okayama University
Sato, Shuhei Okayama University Kaken ID publons researchmap
Iguchi, Toshihiro Okayama University
Mimura, Hidefumi Okayama University
Yasui, Kotaro Okayama Saiseikai General Hospital
Gobara, Hideo Okayama University ORCID Kaken ID publons researchmap
Saika, Takashi Okayama University
Nasu, Yasutomo Okayama University Kaken ID publons researchmap
Kumon, Hiromi Okayama University Kaken ID publons
Kanazawa, Susumu Okayama University Kaken ID publons
抄録
We quantitatively evaluated total and individual renal function by technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) renal scintigraphy before and after radiofrequency ablation (RFA) of renal tumors. Eleven patients who underwent Tc-99m MAG3 renal scintigraphy 1 week before and after RFA were evaluated (7 men and 4 women ; age range : 23-83 years ; mean age : 60.6 years). Five patients had solitary kidneys, and five had normally or minimally functioning contralateral kidneys. One patient had a renal cell carcinoma in the contralateral kidney. One patient with a solitary kidney underwent RFA a second time for a residual tumor. In patients with a solitary kidney, MAG3 clearance decreased after 5 of 6 RFAs, and in patients with a normally functioning contralateral kidney, MAG3 clearance decreased after 4 of 5 RFAs, but no significant differences were observed between before and after treatments. In addition to the total MAG3 clearance, the split MAG3 clearance was evaluated in patients with a normally functioning contralateral kidney. MAG3 clearance decreased in 4 of 5 treated kidneys, while it adversely increased in the contralateral kidneys after 4 of 5 RFAs. No significant differences, however, were observed between before and after treatments. The results of our study revealed no significant differences in sCr, BUN, CCr, or MAG3 clearance between pre- and post-RFA values. These results support data regarding the functional impact and safety of renal RFA in published reports. We evaluated total and individual renal function quantitatively using Tc-99m MAG3 renal scintigraphy before and after treatment. This scintigraphy was very useful in assessing the effects of RFA on renal function.
キーワード
kidney
renal tumor
radiofrequency ablation
Tc-99m MAG3 renal scintigraphy
individual renal function
Amo Type
Article
出版物タイトル
Acta Medica Okayama
発行日
2006-04
60巻
2号
出版者
Okayama University Medical School
開始ページ
85
終了ページ
91
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語
論文のバージョン
publisher
査読
有り
Web of Science KeyUT