ID | 64236 |
フルテキストURL | |
著者 |
Fujii, Yuki
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Matsumoto, Kazuyuki
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
ORCID
Kaken ID
publons
Miyamoto, Kazuya
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Matsumi, Akihiro
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Morimoto, Kosaku
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Terasawa, Hiroyuki
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Yamazaki, Tatsuhiro
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Horiguchi, Shigeru
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
Tsutsumi, Koichiro
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
ORCID
Kaken ID
researchmap
Kato, Hironari
Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Science
ORCID
Kaken ID
researchmap
|
抄録 | Rationale:Duodenal wall perforation by a dislocated biliary stent placed for biliary structure is rare but can be life-threatening. There are few reports on the management of stent-related duodenal perforation. Patient concerns:Three cases included in this study had undergone endoscopic retrograde cholangiopancreatography with placement of a plastic stent for biliary stricture. Two cases had symptoms (fever or abdominal pain), while other case showed no symptom after biliary stent placement. Diagnoses:Dislocation of plastic stents was revealed on computed tomography or endoscopic images. Two patients were diagnosed with duodenal perforation due to distal migration of long stents with a straight shape on the distal side. One patient was diagnosed with fistula formation between the intrahepatic bile duct and duodenum due to perforation of a pigtail stent. Interventions:All cases could successfully be managed endoscopically with closure by hemoclips or stent replacement. Outcomes:All 3 cases were improved after endoscopic treatment without any subsequent intervention. Lessons:Longer stents with a straight distal side are associated with a higher risk of duodenal perforation. Endoscopic management is appropriate as a first-line approach for a clinically stable patient. At the time of stent placement, we should pay attention to the length and type of stent.
|
キーワード | biliary stent
endoscope
migration
perforation
|
発行日 | 2022-12-02
|
出版物タイトル |
MEDICINE
|
巻 | 101巻
|
号 | 48号
|
出版者 | LIPPINCOTT WILLIAMS & WILKINS
|
開始ページ | e31868
|
ISSN | 0025-7974
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
OAI-PMH Set |
岡山大学
|
著作権者 | © 2022 the Author(s).
|
論文のバージョン | publisher
|
PubMed ID | |
DOI | |
Web of Science KeyUT | |
関連URL | isVersionOf https://doi.org/10.1097/MD.0000000000031868
|
ライセンス | https://creativecommons.org/licenses/by/4.0/
|