このエントリーをはてなブックマークに追加
ID 61236
フルテキストURL
fulltext.pdf 6.97 MB
著者
Abe, Yuki Department of Radiological Technology, Graduate School of Health Sciences, Okayama University,
Shimada, Makoto Department of Radiological Technology, Graduate School of Health Sciences, Okayama University,
Takeda, Yoshihiro Department of Radiological Technology, Graduate School of Health Sciences, Okayama University, Kaken ID publons researchmap
Enoki, Taisuke Department of Educational Collaboration, Health and Safety Sciences, Osaka Kyoiku University
Omachi, Kumiko Department of Radiology, Osaka General Medical Center,
Abe, Shuji Department of Radiology, Osaka Women's and Children’s Hospital
抄録
Aim: Metallic components from circular external fixators, including the Ilizarov frame, cause artefacts on X-rays and obstruct clear visualisation of bone detail. We evaluated the ability of tomosynthesis to reduce interference on radiographs caused by metal artefacts and developed an optimal image acquisition method for such cases.
Materials and methods: An Ilizarov frame phantom was constructed using rods placed on the bone for the purpose to evaluate the benefits of tomosynthesis. Distances between the rod and bone and the angle between the rod and X-ray tube orbit were set at three different levels. Filtered backprojection images were reconstructed using two different features of the reconstruction function: THICKNESS−− (CONTRAST4) and THICKNESS++ (METAL4); the first is suitable for improving contrast and the second is suitable for metal artefacts. The peak signal-to-noise ratio (PSNR) was used during image evaluation to determine the influence of the metallic rod on bone structure visibility.
Results: The PSNR increased as the angle between the metal rod and the X-ray tube orbit and the distance between the metallic rod and bone increased. The PSNR was larger when using THICKNESS−− (CONTRAST4) than when using THICKNESS++ (METAL4).
Conclusion: The optimal reconstruction function and image acquisition determined using the metallic rod in this study suggest that quality equal to that without the metallic rod can be obtained.
Clinical significance: We describe an optimised method for image acquisition without unnecessary acquisition repetition and unreasonable posture changes when the bone cannot be adequately visualised.
キーワード
Digital tomosynthesis
Ilizarov, Metal artefacts
Metallic rod, Peak signal-to-noise ratio
X-ray
発行日
2020
出版物タイトル
Strategies Trauma and Limb Reconstruction
15巻
1号
出版者
Jaypee Brothers Medical Publishers
開始ページ
1
終了ページ
6
ISSN
1828-8928
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© The Author(s).
論文のバージョン
publisher
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.5005/jp-journals-10080-1446
ライセンス
https://creativecommons.org/licenses/by-nc/4.0/