このエントリーをはてなブックマークに追加
ID 63524
フルテキストURL
fulltext.pdf 4.79 MB
著者
Tsukada, Keiji Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University Kaken ID researchmap
Hayashi, Minoru Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Kawakami, Taisei Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Adachi, Shoya Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Sakai, Kenji Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University ORCID Kaken ID publons researchmap
Kiwa, Toshihiko Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University ORCID Kaken ID publons researchmap
Ishikawa, Toshiyuki Faculty of Environmental and Urban Engineering Department of Civil, Environmental and Applied System Engineering, Kansai University
Saari, Mohd Mawardi Faculty of Electrical and Electronic Engineering, Universiti Malaysia Pahang
Hori, Kengo Nippon Steel Metal Products Co., Ltd.
Hisazumi, Kazumasa Nippon Steel Corp.
Tominaga, Tomonori Nippon Steel Corp.
抄録
The diagnosis and prevention of the deterioration of iron-steel infrastructure has become an important social issue in recent years. The thickness measurement technique (extremely low-frequency eddy current testing (ELECT)) using a magnetic sensor for detecting steel corrosion at extreme frequency ranges has been previously reported. Using the calibration curves based on the correlation between the phase of the detected magnetic signal and the plate thickness, the plate thickness reduction caused by corrosion can be estimated from the detected phase signal. Iron-steel materials have large changes in electromagnetic characteristics; therefore, the reference calibration data for each type of iron-steel are required for plate thickness estimation. In this study, the effect of electromagnetic characteristics on the magnetic thickness measurement was investigated to improve the thickness estimation. Four types of iron-steel plates (SS400, SM400A, SM490A, and SMA400AW) with thicknesses ranging from 1 mm to 18 mm were measured by ELECT, and the phase change at multiple frequencies of each plate were analyzed. The shift in the phase and linearity regions of the calibration curves for each type of steel plate was observed. To analyze this shift phenomenon, the electromagnetic characteristics (permeability mu and conductivity sigma) of each type of steel were measured. Compared with the permeability mu and conductivity sigma of each steel plate in the applied magnetic field strength range, the product (sigma mu) for various steel plates decreased in the following order: SM400 > SS400 >SMA400AW > SM490A. The product of mu and sigma is related to the skin depth, indicating the electromagnetic wave attenuation and eddy current phase shift in the material. Therefore, each shift in the calibration curve of each type of iron steel is explained by the changes in the parameters sigma and mu.
発行日
2022-03-03
出版物タイトル
AIP Advances
12巻
3号
出版者
AIP Publishing
開始ページ
035109
ISSN
2158-3226
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© 2022 Author(s).
論文のバージョン
publisher
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1063/9.0000250
ライセンス
http://creativecommons.org/licenses/by/4.0/