このエントリーをはてなブックマークに追加
ID 65448
フルテキストURL
著者
Hiranaka, Takaaki Department of Orthopaedic Surgery, Okayama University Hospital
Furumatsu, Takayuki Department of Orthopaedic Surgery, Okayama University Hospital Kaken ID publons
Okazaki, Yuki Department of Orthopaedic Surgery, Okayama University Hospital
Kintaka, Keisuke Department of Orthopaedic Surgery, Okayama University Hospital
Higashihara, Naohiro Department of Orthopaedic Surgery, Okayama University Hospital
Tamura, Masanori Department of Orthopaedic Surgery, Okayama University Hospital
Nakata, Eiji Department of Orthopaedic Surgery, Okayama University Hospital ORCID Kaken ID
Ozaki, Toshifumi Department of Orthopaedic Surgery, Okayama University Hospital Kaken ID publons researchmap
抄録
Background/objective: Accurate tibial tunnel creation is crucial for successful transtibial pullout repair of medial meniscus (MM) posterior root tears (MMPRTs). This study aimed to evaluate the accuracy of the newly developed Zimmer Biomet Root Aiming (ZeBRA) guide for transtibial pullout repair of MMPRTs.Methods: This study included 50 patients who underwent transtibial pullout repair using the Unicorn Meniscal Root (UMR) (n = 25) and ZeBRA (n = 25) guides. The expected anatomic centre (AC) and tibial tunnel centre (TC) were assessed using three-dimensional postoperative computed tomography (CT) images. The expected AC was defined as the centre of the circle tangent to the triangular footprint of the MM posterior root. The expected AC and TC on the tibial surface were assessed using the percentage-based posterolateral location on the tibial surface. The absolute distance between the AC and TC (mm) was evaluated.
Results: The mean AC location was 76.1% +/- 3.1% posterior and 40.8% +/- 2.1% lateral, whereas the mean TC location was 76.7% +/- 5.3% posterior and 37.2% +/- 3.6% lateral using the UMR guide and 75.8% +/- 3.1% posterior and 36.5% +/- 2.4% lateral using the ZeBRA guide. No significant difference was observed in the absolute distance between the UMR and ZeBRA guides (3.9 +/- 1.4 and 3.8 +/- 1.3 mm, respectively; p = 0.617).
Conclusions: The newly developed ZeBRA guide allows accurate tibial tunnel creation, and its accuracy is comparable to that of the conventional UMR guide. Tibial tunnels were created at optimal positions using both guides, and the choice of the guide would depend on the surgeon's preference.
キーワード
Meniscus
Musculoskeletal diseases
Zimmer biomet root aiming guide
Tibial tunnel
Orthopaedic procedures
発行日
2023-04
出版物タイトル
Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology
32巻
出版者
Elsevier (Singapore) Pte Ltd.
開始ページ
1
終了ページ
6
ISSN
2214-6873
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© 2023 Asia Pacific Knee, Arthroscopy and Sports Medicine Society.
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1016/j.asmart.2023.03.001
ライセンス
http://creativecommons.org/licenses/by-nc-nd/4.0/