ID | 61437 |
JaLCDOI | |
フルテキストURL | |
著者 |
Sanki, Tomoaki
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Tetsunaga, Tomonori
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
Furumatsu, Takayuki
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
Yamada, Kazuki
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kawamura, Yoshi
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ozaki, Toshifumi
Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
researchmap
|
抄録 | Intra-operative acetabular fracture is a total hip arthroplasty complication that can occur during cementless cup insertion, especially in osteoporotic patients. We conducted this biomechanical study to investigate the impact resistance of the acetabulum with simulated bones of different density by drop-weight impact testing. Low- and high-density polyurethane foam blocks were used as osteoporotic and healthy bone models, respectively. Polyurethane blocks were used as the acetabular cancellous bone. Composite sheets were used as the acetabu-lum’s medial cortex. The testing revealed that the osteoporotic bone model’s impact resistance was significantly lower than that the healthy bone model’. In the healthy bone model, even thin acetabular cancellous bone with ≥ 1 mm acetabulum medial cortex was less likely to fracture. In the osteoporotic bone model, fracture was pos-sible without ≥ 1 mm medial cortex of the acetabulum and thick acetabular cancellous bone. Although impac-tion resistance differs due to bone quality, the impaction resistance in this osteoporotic bone model was equiv-alent to that healthy bone model’s when a thick medial wall was present. To avoid intra-operative acetabulum fracture, surgeons should consider both the bone quality and the thicknesses of the medial cortex and acetabu-lar cancellous bone.
|
キーワード | intra-operative acetabular fracture
drop weight impact testing
total hip arthroplasty
impact resistance
|
Amo Type | Original Article
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 2021-02
|
巻 | 75巻
|
号 | 1号
|
出版者 | Okayama University Medical School
|
開始ページ | 71
|
終了ページ | 77
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2021 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID |