Iguchi, Toshihiro Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Hiraki, Takao Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Matsui, Yusuke Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Toji, Tomohiro Department of Pathology, Okayama University Hospital
Uka, Mayu Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Tomita, Koji Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Komaki, Toshiyuki Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Umakoshi, Noriyuki Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Mitsuhashi, Toshiharu Center for Innovative Clinical Medicine, Okayama University Hospital
Kanazawa, Susumu Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons
抄録
To evaluate the volume and heat-sink effects of microwave ablation (MWA) in the ablation zone of the normal swine lung. MWA at 100 W was performed for 1, 2, and 3 min in 7, 5, and 5 lung zones, respectively. We assessed the histopathology in the ablation zones and other outcome measures: namely, length of the longest long and short axes, sphericity, ellipsoid area, and ellipsoid volume. The mean long- and short-axis diameters were 22.0 and 14.1 mm in the 1-min ablation zone, 27.6 and 20.2 mm in the 2-min ablation zone; and 29.2 and 21.2 mm in the 3-min ablation zone, respectively. All measures, except sphericity, were significantly less with 1-min ablation than with either 2- or 3-min ablation. There were no significant differences between the 2- and 3-min ablation zones, but all measures except sphericity were larger with 3-min ablation. Although there were no blood vessels that resulted in a heat-sink effect within the ablation zones, the presence of bronchi nearby in 5 lung ablation zones resulted in reduced ablation size. In high-power, short-duration MWA, the lung ablation volume was affected by ablation time. Some ablations showed that a heat-sink effect by a neighboring bronchus might occur.
キーワード
microwave ablation
lung
ablation zone
heat-sink effect
swine
Amo Type
Original Article
出版物タイトル
Acta Medica Okayama
発行日
2022-02
76巻
1号
出版者
Okayama University Medical School
開始ページ
57
終了ページ
62
ISSN
0386-300X
NCID
AA00508441
資料タイプ
学術雑誌論文
言語
英語