Published by Misasa Medical Center, Okayama University Medical School
Published by Misasa Medical Center, Okayama University Medical School

<Formerly known as>
岡大三朝分院研究報告 (63号-72号) 環境病態研報告 (57号-62号)
岡山大学温泉研究所報告 (5号-56号) 放射能泉研究所報告 (1号-4号)

<Availability>
Some items are not available because of decision by its author or publisher.

温泉水配湯管内の温泉沈殿物について

Furuno, Katsushi
Tetsumoto, Junko
Aoki, Hiroko
Mifune, Masaaki
Morinaga, Hiroshi
Fukushima, Satoru
Wada, Hiroaki
Abstract
Sinter deposit in a distributing pipe used for about fifteen years in Misasa radioactive hot springs was investigated. The results were as follows; 1. The metal elements in this deposit were quaIi. tatively analysed by spectraspan plasma emission spectrophotometry (SPES), by fluorescent X-ray spectrometry, and following elements were detected; B, Na, Mg, AI, K, Ca, Mn, Fe, Cu, Zn, As, Sr, Ba and Pb. 2. The metal elements in this deposit were quantatively analysed by SPES and atomic absorption spectrophotometry, and following elements were determined; Fe : 508.7, As: 26.40, Ca: 7.85, Mn : 2.00, Al : 1.80, Na: 1.60, Zn: 1.33, K: 0.80, Cu: 0.67, Sr: 0.47, Mg: 0.35, Ba: 0.33 and B : 0.30 mg per gram. The color of this deposit was red brown, and the main component was ferric oxide. 3. Radioactive elements in this deposit were detected by autoradiography and radioluxography. Among the radioactive elements, concentration of radium was 320.5×10(-12)g/g (313.0×10(-12)Ci/g).
Note
原著論文 (Original Papers)
ISSN
0369-7142
NCID
AN00032853