このエントリーをはてなブックマークに追加
ID 15456
Eprint ID
15456
フルテキストURL
著者
山本 恭二 Department of Mechanical Engineering
Jiao Xuezhen The Graduate School of Natural Science and Technology
抄録
An experimental investigation has been made of the cyclone dust collector with a perforated internal rotating cylinder. The size of the rotating cylinder is of 0.5D, where D is the diameter of the cyclone body, and is the same size as the outlet tube. The dust collection efficiency as well as the pressure loss has been measured when the inlet flow speed is 9 ~ 21 m/s and the rotating speed of the cylinder is 37 ~ 63 m/s. The velocity and pressure distributions were also measured. It is found that the collection efficiency decreases and the pressure loss increases as the rotating speed increases. It is also shown that both the inward radial velocity and the upward vertical velocity become large as the rotating cylinder increases its speed. As a whole, the rotation of the internal cylinder makes worse performance of the cyclone dust collector.
発行日
1994-03-15
出版物タイトル
Memoirs of the Faculty of Engineering, Okayama University
出版物タイトル(別表記)
岡山大学工学部紀要
28巻
2号
出版者
Faculty of Engineering, Okayama University
出版者(別表記)
岡山大学工学部
開始ページ
21
終了ページ
31
ISSN
0475-0071
NCID
AA10699856
資料タイプ
紀要論文
言語
English
論文のバージョン
publisher
査読
無し
Eprints Journal Name
mfe